Samsung RFG293HABP User Manual (user Manual) (ver.0.0) (English) - Page 18
INSTALLING A WATER LINE KIT, Connecting to the water supply line
UPC - 036725569652
View all Samsung RFG293HABP manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 18 highlights
Setting up your French Door Refrigerator INSTALLING A WATER LINE KIT To help promote better health, the water filter removes unwanted particles from your water. However, it does not sterilize or destroy microorganisms. You may need to purchase a water purifying system to do that. For the ice maker to operate properly, a water pressure of 20~125 psi is required. Within this water pressure range, a 170 cc (5.75 oz.) cup fills in about 10 seconds. If the refrigerator is installed in an area with low water pressure (below 20psi), you can install a booster pump to compensate for the low pressure. Water line installation kits are available at extra cost from your dealer. We recommend using a water line installation kit that contains copper tubing and ¼" compression nut. Connecting to the water supply line 1. First, shut off the main water supply. 2. L ocate the nearest cold water drinking line and install the pipe clamp and shut off valve. Cold water line Pipe clamp Shut off valve 3. C onnect the water line installation kit to shut off valve. Check for leaks, then go to Connecting the Water Supply Line to the Refirgerator on the next page. Cold water line Pipe clamp Shut off valve Water line installation kit 18_ Setting Up