Samsung RS2533SW User Manual (user Manual) (ver.1.0) (English) - Page 36
Ambient Room Temperature Limits
View all Samsung RS2533SW manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 36 highlights
Ambient Room Temperature Limits This appliance is designed to operate at the ambient temperatures specified by its temperature class marked on the rating plate. Temperature Class Symbol Extended Temperate SN Temperate N Subtropical ST Tropical T Ambient Temperature Maximum Minimum 32°C (90°F) 32°C (90°F) 38°C (100°F) 43°C (109°F) 10°C (50°F) 16°C (61°F) 18°C (64°F) 18°C (64°F) NOTE: The internal temperature may be affected by such factors as the location of the appliance, ambient temperature and the frequency with which you open the doors. Adjust the temperature as required to compensate for these factors.
Ambient Room Temperature Limits
This appliance is designed to operate at the ambient temperatures specified by its temperature
class marked on the rating plate.
NOTE:
The internal temperature may be affected by such factors as the location of the appliance,
ambient temperature and the frequency with which you open the doors.
Adjust the temperature as required to compensate for these factors.
Temperature
Symbol
Ambient Temperature
Class
Maximum
Minimum
Extended Temperate
SN
32
°
C (90
°
F)
10
°
C (50
°
F)
Temperate
N
32
°
C (90
°
F)
16
°
C (61
°
F)
Subtropical
ST
38
°
C (100
°
F)
18
°
C (64
°
F)
Tropical
T
43
°
C (109
°
F)
18
°
C (64
°
F)