Samsung UF-80DX Reference Guide - Page 5
Note 1], Note 2]
View all Samsung UF-80DX manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 5 highlights
English French RS232C Command Code (UF-80) Command Focus FAR Focus NEAR Zoom Tele Zoom Wide Iris Target Red Target Blue Target Focus Target Zoom Target Focus/Zoom concurrent Target PC Transmit Data to MICOM 1st 0 x 25 0 x 26 0 x 41 0 x 43 0 x 44 0 x 45 0 x 46 0 x 47 2nd 0 x 00 0 x 00 0 x 00 0 x 00 0 x 00 0 x 00 0 x 00 0 x 00 0 x 00 0 x 05 0 x 0A 3rd 4th 0 x 05 0 x 0A 0 x 00 0 x 00 0 x 05 0 x 0A 0 x 00 0 x 00 0 x 00 0 x 00 "data" "data" 0 x 00 "data" "MSB data" "LSB data" "MSB data" "LSB data" "zoom MSB" "zoom LSB" "focus MSB" "focus LSB" PC Receive Data from MICOM 1st 2nd 3rd 4th Remark "ACK data" 0 x 05 0 x 25 "ACK data" 0 x 0A 0 x 00 0 x 00 "ACK data" 0 x 05 0 x 26 "ACK data" 0 x 0A 0 x 00 0 x 00 0 x 41 "ACK data" 0 x 00 "data" Range: "1~120" 0 x 43 "ACK data" 0 x 00 "data" Range: "1~200" 0 x 44 "ACK data" 0 x 00 "data" Range: "1~200" 0 x 45 "ACK data" "MSB data" "LSB data" (1)Range: "0~2225" 0 x 46 0 x 47 "ACK data" "MSB data" "LSB data" Range: "0~1904" "ACK data" "zoom MSB" "zoom LSB" (1)Focus: "0~2225" "ACK data" "focus MSB" "focus LSB" Zoom: "0~1904" (1)Drive Stop 0 x 2F 0 x 00 0 x 05 0 x 00 0 x 2D "ACK data" 0 x 05 0 x 00 [Note 1] Depending of the zoom amount, the range of focus data will be changed. You can figure it out to see page 4. ("Focus-Status[Max]", "Focus-Status[Min]") [Note 2] Above 10 Command (Iris up/down ,Red up/down, Blue up/down, Focus far/near, Zoom tele/wide) will go to all the way once you execute it. "Drive Stop" can stop those command in certain point that you want. German Italian Spanish 5