Notes for Communication
UPC - 086483065156
View all Sanyo CE42LM4WPN-NA manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 5 highlights
3. Notes for Communication 3.1 The TV command is defined one command/one line that starts with "C" and ends with carriage return (0x0D). 3.2 There are two types of commands, Functional Execution Commands and Status Read Commands. [Example] Functional Execution Command: "C05" [CR] Status Read Command: "CR0" [CR] 3.3 When it takes more than one second to receive one command, the function is not executed. When it takes more than one second until the TV receives carriage return since it has received the first data "C", it clears the information of buffer. 3.4 For the command pipelining, wait interval of 100 ms after the response. More than 100ms Command PC → TV "C""0""7" CR Next Command TV → PC ACK CR Carriage Return (a few ms ~ 5s) 3.4.1 When a command is issued before receiving response, the function is not executed properly. 3.4.2 Except when there is no response for 5 seconds. 3.5 It takes about 5 seconds for internal initialization after plugging in AC power. During this time, it cannot process commands. Do not issue any command. 3.6 The number of characters of response for Status Read Commands depends on commands. Please see [7. Status Read Command]. 3.7 Characters for commands must be Capital (A - Z). Ver. Page 4