Sanyo CE52SR2 Owner's Manual - Page 11
INSTALLATION MODE, IP Address/Subnet/Gateway/DNS
UPC - 086483075155
View all Sanyo CE52SR2 manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 11 highlights
GB INSTALLATION MODE GB Installation Mode Installation Mode G2.02 0000 On program Tuner Menu Max Volume Winter mode RC inhibition Child Lock Address Baud rate Panel protection AV Auto shut off Network Standby On Timer Function LED light setting DCR Network initial Temperature Error IP Address Subnet Gateway DNS Off Off 63 Off Off Off 0 19200 Off Off On Off Off Off >>> 0 000000000000 000000000000 000000000000 000000000000 Select Adjust MENU Exit This LCD monitor allows you to set up the following: SETTING PROCEDURE 1. Press and hold the GREEN button on the remote control for 5 seconds. (Installation Mode will appear) 2. Use the 5 or 6 button to highlight each option, use the 1 or 2 button to adjust each option. Press the MENU button to exit the mode. n On Program Select ON program using the 5 or 6 button, select the start up position using the 1 or 2 buttons. (Off/AV1/RGB/AV2/AV3/PC/DVI or Network) n Max Volume Select Max volume using the 5 or 6 button, use the 1 or 2 buttons to set the maximum volume required. n Winter mode This Function can be activated when the LCD monitor is used during cold temperature conditions, approximately 38˚F/4˚C or below to maintain picture performance. Using the 5 or 6 button select winter mode, once highlighted you can select ON or OFF by pressing the 1 or 2 button. IMPORTANT: The AC cord should not be disconnected during the operation of Winter mode function. When in winter mode, power consumption is higher than normal standby consumption. This is entirely due to the operation of heating circuitry. We strongly recommend to turn off Winter mode when the ambient temperature is above 38˚F/4˚C. n RC inhibition You can prevent unwanted remote control operation by selecting RC Inhibition. Select using the 5 or 6 button. Press the 1 or 2 button to select On or Off. To re-instate RC operation press and hold the green button on the remote control and select RC inhibition OFF. n Child Lock You can prevent unwanted operation of the LCD monitor via the buttons on the rear of the monitor. Select using the 5 or 6 button. Press the 1 button to select On or OFF. The "Child Lock" OSD will appear if buttons are pressed when child lock is On. ✐ Standby operates normally when childlock is set "On". n Address Set the address for the LCD monitor (0 ~ 999). ¡Setting the monitor address in RS232 mode Each monitor can have a specific Address, which helps command that monitor individually and will not effect to other monitors connected to a controlling PC Address format command. The addressing format command is used for operating multiple monitor sets from a single PC via the RS232C command line. n Baud rate Select Baud rate using the 5 or 6 button. To set transmission speed RS232 or LD-NET communication for 19200 or 9600 Baud rate by pressing the 1 or 2 button. n Panel protection To prevent image sticking which may occur showing still picture for a long time, select "Panel Protect" using the 5 or 6 button, once highlighted you can select ON or OFF by pressing the 1 or 2 button. n AV Auto shut off With no picture input signal to AV1, RGB, AV2(YPbPr), AV3, DVI, Network, set turns off automatically. Select "AV Auto Shut Off" using the 5 or 6 button, once highlighted you can select On or Off by pressing the 1 or 2 button. n Network Standby You can save power consumption selecting "Off" at Network Standby in Installation mode, both RS232C and LD-NET do not functional. To make them functional, select "ON" in this menu. n On Timer Function You can save power consumption selecting "Off" at On Timer function in Installation mode. On Timer in Time menu does not functional. To make them functional, select "ON" in this menu. n LED Light setting Select LED Light setting using the 5 or 6 button, once highlighted you can select On or Off by pressing the 1 or 2 button. n DCR The picture contrast improved while DCR is ON. Select DCR using the 5 or 6 button, once highlighted you can select On or Off by pressing the 1 or 2 button. n Network Initial This function automatically installs the IP Address, Subnet, Gateway and DNS information. n Temperature Error The recorded number of abnormal temperature is occurred is indicated here. n IP Address/Subnet/Gateway/DNS These 4 items display the LD-Net information. If LD-NET is NOT connected, all the items would be displayed as "000000000000". ✐ Disconnecting the mains supply before exiting Installation Mode will cancel the following features On program, RC inhibition, Address and Baud Rate. 11