Sanyo PDG-DSU30 RS232 Expand - Page 40
CR_BACKGND Command, 10.5 CR_LOGO Command, 10.6 CR_HIGHLAND Command, 10.7 CR_ON-STA Command, 10.
UPC - 086483076596
View all Sanyo PDG-DSU30 manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 40 highlights
PDG-DSU30 Expand Serial Command Functional Specifications 9.10.4 CR_BACKGND Command Command "CR_BACKGND" [CR] Details Get setting status of Screen for no signal Acceptable "000_%a" [CR] Response "BLUE Blue Back is selected "BLACK Black Back is selected %a "RED Red Back is selected "GREEN Green Back is selected "WHITE White Back is selected Unacceptable "Error Code" [CR] 9.10.5 CR_LOGO Command Command "CR_LOGO"[CR] Details Get setting status of Logo Acceptable "000_%1"[CR] Response %1 "ON Logo is ON "OFF Logo is OFF Unacceptable "Error Code" [CR] 9.10.6 CR_HIGHLAND Command Command "CR_HIGHLAND" [CR] Details Get status of High;amd. Acceptable "000_%1" [CR] Correspondence %1 "ON Set High land ON "OFF Set High land OFF Unacceptable "Error Code" [CR] 9.10.7 CR_ON-STA Command Command "CR_ON-STA"[CR] Details Get setting status of Direct Power On Acceptable "000_%1"[CR] Response %1 "ON Direct Power On is ON "OFF Direct Power On is OFF Unacceptable "Error Code" [CR] 9.10.8 CR_P-MANETIME Command Command "CR_P-MANETIME" [CR] Details Get value of Power management timer Acceptable "000_%1" [CR] Correspondence %1 "000" - "180"(minutes) Unacceptable "Error Code" [CR] 40 / 42