CR_COLTEMP Command, 4.11 CR_NZRED Command, 4.12 CR_PROGV Command, 4.13 CR_IMAGE Command
UPC - 086483076336
View all Sanyo PLC-XU300A manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 45 highlights
PLC-XU300/350 Expand Serial Command Functional Specifications 9.4.10 CR_COLTEMP Command Command "CR_COLTEMP"[CR] Details Get Color Temp. setting value Acceptable "000_%a"[CR] "000 Xlow "001 Low "002 Mid Response %a "003 High "BLACK Blackboard(Green) mode selected "COLOR Colorboard selected "BLANK White Balance has been changed Unacceptable "Error Code"[CR] 9.4.11 CR_NZRED Command Command "CR_NZRED"[CR] Details Get setting status of Noise Reduction Acceptable "000_%1"[CR] "L1" -------- Noise Reduction for moving image Response %1 "L2" -------- Noise Reduction for still image "OFF" ----- Noise Reduction is OFF Unacceptable "Error Code"[CR] 9.4.12 CR_PROGV Command Command "CR_PROGV"[CR] Details Get setting status of Progressive scan Acceptable "000_%a"[CR] "L1 Progressive Mode L1 is selected Response %a "L2 Progressive Mode L2 is selected "FILM Progressive Model FILM is selected "OFF Progressive scan is disabled Unacceptable "Error Code"[CR] 9.4.13 CR_IMAGE Command Command "CR_IMAGE"[CR] Details Get image setting status Required data "CUSTOM1" to "CUSTOM4" is the same as "Image1" to "Image4" displayed when selecting IMAGE on OSD menu Acceptable "000_%a"[CR] "DYNAMIC Dynamic "STAND Standard "REAL Real Response %a "CINEMA Cinema "BLACKBOARD Blackboard "COLORBOARD Colorboard "CUSTOM1"~"CUSTOM4 Image1~4 Unacceptable "Error Code"[CR] ---- When the command is invalid due to condition such as Input source 44 / 66