Sanyo VCC-3944 Instruction Manual - Page 11

Iris function setting, CAUTION, When using an auto-iris lens for indoor, outdoor use, Gain up

Page 11 highlights

SETTINGS s Iris function setting 1 This should normally be set to the down (AI) position. Use a manual or fixed iris lens and set the lens aperture to the shortest F stop. Set the switch 1 to the up (EI) position. EI AI Note: Please refer to the specifications for dynamic range of the electronic iris. CAUTION: • The electronic iris is suitable for normal indoor use. When the switch 1 is set to the up (EI) position, do not use an auto-iris lens. • If used under fluorescent light, the image may flicker. In such a case, change to incandescent lighting or set the switch 1 to the down (AI) position and use an auto-iris lens. • When shooting bright subjects, pay attention to the light angle in order to avoid or minimize the smear phenomenon effect. When using an auto-iris lens (for indoor/ outdoor use) Set the switch 1 to the down (AI) position. CAUTION: If conditions are outside the electronic iris operation range or more than the maximum illumination, it will cause saturation of the CCD. In that case, use a manual iris lens. s Gain up setting 2 Switch 2 should normally be set to "NORM". If the monitoring location is dark and you would like to increase the luminance (brightness), set switch 2 to "HI". Note: If switch 2 is set to "HI", the images from the monitoring location will become brighter, but interference may become more noticeable. HI NORM 10 English

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20

10
English
SETTINGS
Iris function setting
1
This should normally be set to the down (
AI
) position.
Use a manual or fixed iris lens and set the lens aperture to the
shortest F stop. Set the switch
1
to the up (
EI
) position.
Note:
Please refer to the specifications for dynamic range of
the electronic iris.
CAUTION:
The electronic iris is suitable for normal indoor use. When
the switch
1
is set to the up (
EI
) position, do not use an
auto-iris lens.
If used under fluorescent light, the image may flicker. In
such a case, change to incandescent lighting or set the
switch
1
to the down (
AI
) position and use an auto-iris
lens.
When shooting bright subjects, pay attention to the light
angle in order to avoid or minimize the smear phenomenon
effect.
When using an auto-iris lens (for indoor/
outdoor use)
Set the switch
1
to the down (
AI
) position.
CAUTION:
If conditions are outside the electronic iris operation range or
more than the maximum illumination, it will cause saturation of
the CCD. In that case, use a manual iris lens.
Gain up setting
2
Switch
2
should normally be set to
NORM
. If the monitoring
location is dark and you would like to increase the luminance
(brightness), set switch
2
to
HI
.
Note:
If switch
2
is set to
HI
, the images from the
monitoring location will become brighter, but
interference may become more noticeable.
AI
EI
NORM
HI