Check RPM Sensor (requires shroud removal) RPM sensor should be aligned with magnet and connected to data cable. Realign sensor if necessary. Replace if there is any damage to the sensor or the connecting wire. Console shuts off (enters sleep Check data cable integrity mode) while in use All wires in the cable should be intact. If any are cut or crimped, replace cable. Check data cable connections/orientation Be sure cable is connected securely and oriented properly. Small latch on connector should line up and snap into place. Check magnet position (requires shroud removal) Magnet should be in place on pulley. Check RPM Sensor Contact Customer Care for further assistance. Unit rocks/does not sit level Check leveler adjustment Leveling feet may be turned in or out to level bike. Check surface under unit Adjustment may not be able to compensate for extremely uneven surfaces. Move bike to level area. Pedals loose/unit difficult to pedal Check pedal to crank connec- Pedal should be tightened tion securely to crank. Be sure con- nection is not cross-threaded. Check crank to axle connection Crank should be tightened securely to axle. Clicking sound when pedaling Check pedal to crank connec- Remove pedals and reattach tion fully. Seat post movement Check locking pin Be sure adjustment pin is locked into one of the seat post adjustment holes. Check adjustment knob Be sure knob is securely tightened. 26