Seagate 10K.3 Savvio 10K.3 SAS Product Manual - Page 34
Power dissipation
UPC - 715663213796
View all Seagate 10K.3 manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 34 highlights
6.3 Power dissipation 300 GB models in 3 Gbit operation Typical power dissipation under idle conditions in 3Gb operation is 3.79 watts (12.93 BTUs per hour). To obtain operating power for typical random read operations, refer to the following I/O rate curve (see Figure 18). Locate the typical I/O rate for a drive in your system on the horizontal axis and read the corresponding +5 volt current, +12 volt current, and total watts on the vertical axis. To calculate BTUs per hour, multiply watts by 3.4123. Figure 18. 300GB (at 3 Gbit) DC current and power vs. input/output operations per second 26 Savvio 10K.3 SAS Product Manual, Rev. D
26
Savvio 10K.3 SAS Product Manual, Rev. D
6.3
Power dissipation
300 GB models in 3 Gbit operation
Typical power dissipation under idle conditions in 3Gb operation is 3.79 watts (12.93 BTUs per hour).
To obtain operating power for typical random read operations, refer to the following I/O rate curve (see Figure
18). Locate the typical I/O rate for a drive in your system on the horizontal axis and read the corresponding +5
volt current, +12 volt current, and total watts on the vertical axis. To calculate BTUs per hour, multiply watts by
3.4123.
Figure 18.
300GB (at 3 Gbit) DC current and power vs. input/output operations per second