Seagate Barracuda XT Barracuda XT Series SATA Product Manual - Page 19

Test for Prominent Discrete Tones (PDTs), 2.9 Electromagnetic immunity, Description

Page 19 highlights

www.seagate.com Drive Specifications 2.8.1 Test for Prominent Discrete Tones (PDTs) Seagate follows the ECMA-74 standards for measurement and identification of PDTs. An exception to this process is the use of the absolute threshold of hearing. Seagate uses this threshold curve (originated in ISO 3897) to discern tone audibility and to compensate for the inaudible components of sound prior to computation of tone ratios according to Annex D of the ECMA-74 standards. 2.9 Electromagnetic immunity When properly installed in a representative host system, the drive operates without errors or degradation in performance when subjected to the radio frequency (RF) environments defined in the following table: Table 5 Radio frequency environments Test Description Performance level Reference standard Electrostatic Contact, HCP, VCP: ± 4 kV; Air: ± 8 kV B discharge EN61000-4-2: 95 Radiated RF 80 to 1,000MHz, 3 V/m, A immunity 80% AM with 1kHz sine 900MHz, 3 V/m, 50% pulse modulation @ 200Hz EN61000-4-3: 96 ENV 50204: 95 Electrical fast ± 1 kV on AC mains, ± 0.5 kV on external I/O B transient EN61000-4-4: 95 Surge immu- ± 1 kV differential, ± 2 kV common, AC mains B nity EN61000-4-5: 95 Conducted RF 150kHz to 80MHz, 3 Vrms, 80% AM with 1kHz A immunity sine EN61000-4-6: 97 Voltage dips, interrupts 0% open, 5 seconds 0% short, 5 seconds 40%, 0.10 seconds 70%, 0.01 seconds C EN61000-4-11: 94 C C B Barracuda XT SATA Product Manual, Rev. D 19

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42

Barracuda XT SATA Product Manual, Rev. D
19
www.seagate.com
Drive Specifications
2.8.1
Test for Prominent Discrete Tones (PDTs)
Seagate follows the ECMA-74 standards for measurement and identification of PDTs. An exception to this
process is the use of the absolute threshold of hearing. Seagate uses this threshold curve (originated in ISO 389-
7) to discern tone audibility and to compensate for the inaudible components of sound prior to computation of
tone ratios according to Annex D of the ECMA-74 standards.
2.9
Electromagnetic immunity
When properly installed in a representative host system, the drive operates without errors or degradation in
performance when subjected to the radio frequency (RF) environments defined in the following table:
Table 5
Radio frequency environments
Test
Description
Performance level
Reference
standard
Electrostatic
discharge
Contact, HCP, VCP: ± 4 kV; Air: ± 8 kV
B
EN61000-4-2: 95
Radiated RF
immunity
80 to 1,000MHz, 3 V/m,
80% AM with 1kHz sine
900MHz, 3 V/m, 50% pulse modulation @
200Hz
A
EN61000-4-3: 96
ENV 50204: 95
Electrical fast
transient
± 1 kV on AC mains, ± 0.5 kV on external I/O
B
EN61000-4-4: 95
Surge immu-
nity
± 1 kV differential, ± 2 kV common, AC mains
B
EN61000-4-5: 95
Conducted RF
immunity
150kHz to 80MHz, 3 Vrms, 80% AM with 1kHz
sine
A
EN61000-4-6: 97
Voltage dips,
interrupts
0% open, 5 seconds
0% short, 5 seconds
40%, 0.10 seconds
70%, 0.01 seconds
C
C
C
B
EN61000-4-11: 94