Seagate ST2000VM002 Pipeline HD.2 Series SATA Product Manual - Page 23
Test for Prominent Discrete Tones PDTs, Table 5, Drive A-weighted Sound Power Levels SWL, BA, Table
View all Seagate ST2000VM002 manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 23 highlights
2.10 Acoustics emissions Drive emission of sound is measured consistent with the ECMA-74 and its referenced standards. Testing is conducted at room temperature (approximately 25 degrees C). Emission levels are reported as the total A-weighted sound power levels for, steady state, idle and active (seek) modes of operations. Table 5: Drive A-weighted Sound Power Levels (SWL, BA) 1000GB models 500, 320, 250 and 160GB models Idle[1] 2.1 bels (typ.) 2.3 bels (max.) 1.9 bels (typ.) 2.1 bels (max.) CE seek profile 2.4 bels (typ.) 2.5 bels (max.) 2.3 bels (typ.) 2.4 bels (max.) [1] During periods of drive idle, some offline activity may occur according to the S.M.A.R.T. specification, which may increase acoustic and power to operational levels. Test for Prominent Discrete Tones (PDTs) Seagate follows the ECMA-74 standards for measurement and identification of PDTs. An exception to this process is the use of the absolute threshold of hearing. Seagate uses the lower limit for the threshold curve* to discern tone audibility and to compensate for the inaudible components of sound prior to computation of tone ratios according to Annex D of the ECMA-74 standards. * Defined as the median curve given by ISO 389-7 (Tf curve) minus 10dB at all frequencies. 2.11 Electromagnetic immunity When properly installed in a representative host system, the drive operates without errors or degradation in performance when subjected to the radio frequency (RF) environments defined in the following table: Table 6: Radio frequency environments Test Electrostatic discharge Radiated RF immunity Electrical fast transient Surge immunity Conducted RF immunity Voltage dips, interrupts Description Contact, HCP, VCP: ± 4 kV; Air: ± 8 kV 80 to 1,000MHz, 3V/m, 80% AM with 1kHz sine 900MHz, 3V/m, 50% pulse modulation @ 200Hz ± 1kV on AC mains, ± 0.5kV on external I/O ± 1kV differential, ± 2kV common, AC mains 150kHz to 80MHz, 3Vrms, 80% AM with 1kHz sine 0% open, 5 seconds 0% short, 5 seconds 40%, 0.10 seconds 70%, 0.01 seconds Performance level B Reference standard EN61000-4-2: 95 A EN61000-4-3: 96 ENV50204: 95 B EN61000-4-4: 95 B EN61000-4-5: 95 A EN61000-4-6: 97 C EN61000-4-11: 94 C C B Pipeline HD.2 Series SATA Product Manual, Rev. G 17