When a region of LBA's are erased via cryptographic erase, as part of the erase, the drive shall unmap those LBAs. If the host attempts to access an unmapped or trimmed LBA, the drive shall return scrambled data. For a given LBA, the data shall be identical from access to access, until that LBA is either updated with actual data from the host or that LBA is cryptographically erased. The drive shall report a value of '0' in the LBPRZ field returned in the READ CAPACITY (16) parameter data. If the host attempts to access an unmapped LBA on a drive that has been formatted with Protection Information (PI), the drive shall return scrambled PI data for that LBA. Depending on the value of the RDPROTECT field in the data-access command CDB, this may result in the drive returning a standard PI error to the host. If the host reduces the addressable capacity of the drive via a MODE SELECT command, the drive shall unmap or trim any LBA within the inaccessible region of the device. Additionally, an UNMAP command is not permitted on a locked band. Table 3: PI and SED Drive Configuration PI Setting PROT_EN bit LBPME bit LBPRZ bit PI Check Requested DATA Returned for Thin Provisioned LBA PI Returned for Thin Provisioned LBA PI Check Performed Error reported to Host Drive Configuration Standard Disabled Enabled 0 1 1 1 1 1 N/A Yes No 0x00 0x00 0x00 None N/A No 0xFF No No 0xFF No No Disabled 0 1 0 N/A Random None N/A No SED Enabled 1 1 0 Yes No None Random None Yes Yes Scrambled PI data No No 10 Pulsar XT.2 SAS Product Manual, Rev. B