Seagate ST300MP0014 Savvio 15K.1 FC User Guide - Page 63
Inquiry data
View all Seagate ST300MP0014 manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 63 highlights
9.3.1 Inquiry data Table 16 lists the Inquiry command data that the drive should return to the initiator per the format given in the Fibre Channel Interface Manual. Table 16: Savvio inquiry data Bytes 0-15 16-31 32-47 48-63 64-79 80-95 96-111 112-127 128-143 Data (hex) 00 00 03** 12 8B 00 PP 0A 53 45 41 47 41 54 45 20 Vendor ID [53 54 39 37 33 34 35 31 46 43 20] 20 20 20 20 20 Product ID R# R# R# R# S# S# S# S# S# S# S# S# 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 43 6F 70 79 72 69 67 68 74 20 28 63 29 20 32* *Copyright 30* 30* 37* 20 53 65 61 67 61 74 65 20 41 6C 6C 20 notice 72 69 67 68 74 73 20 72 65 73 65 72 76 65 64 20 * Copyright year (changes with actual year). ** 02 = SCSI-2 implemented with some SCSI-3 features (default). 03 = SCSI-3 implemented. PP 50 = Inquiry data for an Inquiry command received on Port A. 70 = Inquiry data for an Inquiry command received on Port B. R# Four ASCII digits representing the last four digits of the product firmware release number. S# Eight ASCII digits representing the eight digits of the product serial number. [ ] Bytes 18 through 26 reflect model of drive. The table above shows the hex values for Model ST973451FC. Refer to the values below for the values of bytes 18 through 26 of you particular model: ST973451FC ST936751FC 53 54 39 37 33 34 35 31 46 43 20 53 54 39 33 36 37 35 31 46 43 20 Savvio 15K.1 FC Product Manual, Rev. B 55