Seagate ST3200822AS Product Manual - Page 16

write electronics are in power-down mode. - model

Page 16 highlights

• Operating power and current Operating power is measured using 40 percent random seeks, 40 percent read/write mode (1 write for each 10 reads) and 20 percent drive idle mode. • Idle mode power Idle mode power is measured with the drive up to speed, with servo electronics active and with the heads in a random track location. • Standby mode During Standby mode, the drive accepts commands, but the drive is not spinning, and the servo and read/ write electronics are in power-down mode. Table 4: DC power requirements (example of 160GB models supporting NCQ[1]) Power dissipation (watts) Spinup Idle Idle (with offline activity) [2] Operating (40% r/w, 40% seek, 20% inop.) Seeking Standby/Sleep Average (watts, 25° C) - 7.5 9.3 12.0 12.5 1.0 5V typ amps - 0.487 0.875 0.631 0.405 0.185 12V typ amps 2.8 (peak) 0.422 0.41 0.737 0.873 0.006 Table 5: DC power requirements (example of 160GB and 200GB models not supporting NCQ) Power dissipation (watts) Spinup Idle Idle (with offline activity) [2] Operating (40% r/w, 40% seek, 20% inop.) Seeking Standby/Sleep Average (watts, 25° C) - 7.5 9.3 12.1 12.5 2.0 5V typ amps - 0.482 0.587 0.638 0.412 0.367 12V typ amps 2.8 (peak) 0.424 0.53 0.739 0.87 0.014 [1] NCQ may not be enabled during power measurements. [2] During periods of drive idle, some offline activity may occur according to the S.M.A.R.T. specification, which may increase acoustic and power to operational levels. 8 Barracuda 7200.7 Serial ATA Product Manual, Rev. N

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54

8
Barracuda 7200.7 Serial ATA Product Manual, Rev. N
Operating power and current
Operating power is measured using 40 percent random seeks, 40 percent read/write mode (1 write for each
10 reads) and 20 percent drive idle mode.
Idle mode power
Idle mode power is measured with the drive up to speed, with servo electronics active and with the heads in
a random track location.
Standby mode
During Standby mode, the drive accepts commands, but the drive is not spinning, and the servo and read/
write electronics are in power-down mode.
[1]
NCQ may not be enabled during power measurements.
[2]
During periods of drive idle, some offline activity may occur according to the S.M.A.R.T. specification,
which may increase acoustic and power to operational levels
.
Table 4:
DC power requirements (example of 160GB models supporting NCQ
[1]
)
Power dissipation (watts)
Average
(watts, 25° C)
5V typ
amps
12V typ amps
Spinup
2.8 (peak)
Idle
7.5
0.487
0.422
Idle (with offline activity)
[2]
9.3
0.875
0.41
Operating (40% r/w, 40% seek, 20% inop.)
12.0
0.631
0.737
Seeking
12.5
0.405
0.873
Standby/Sleep
1.0
0.185
0.006
Table 5:
DC power requirements (example of 160GB and 200GB models not supporting NCQ)
Power dissipation (watts)
Average
(watts, 25° C)
5V typ
amps
12V typ amps
Spinup
2.8 (peak)
Idle
7.5
0.482
0.424
Idle (with offline activity)
[2]
9.3
0.587
0.53
Operating (40% r/w, 40% seek, 20% inop.)
12.1
0.638
0.739
Seeking
12.5
0.412
0.87
Standby/Sleep
2.0
0.367
0.014