Seagate ST3250623A Barracuda 7200.8 PATA Product Manual - Page 37

Description, Value - st3250823as sata drive

Page 37 highlights

Word 59 60-61 62 63 64 65 66 67 68 69-74 75 76-79 80 81 82 83 84 85 86 87 88 89 90 92 93 95-99 100-103 104-127 Description Number of sectors transferred during a Read Multiple or Write Multiple command Total number of user-addressable LBA sectors available (see Section 2.2 for related information) *Note: The maximum value allowed in this field is: 0FFFFFFFh (268,435,455 sectors, 137 Gbytes). Drives with capacities over 137 Gbytes will have 0FFFFFFFh in this field and the actual number of useraddressable LBAs specified in words 100-103. This is required for drives that support the 48-bit addressing feature. Retired Multiword DMA active and modes supported (see note following this table) Advanced PIO modes supported (modes 3 and 4 supported) Minimum multiword DMA transfer cycle time per word (120 nsec) Recommended multiword DMA transfer cycle time per word (120 nsec) Minimum PIO cycle time without IORDY flow control (240 nsec) Minimum PIO cycle time with IORDY flow control (120 nsec) ATA-reserved Queue depth SATA-specific Major version number Minor version number Command sets supported Command sets supported Command sets support extension Command sets enabled Command sets enabled Command sets enable extension Ultra DMA support and current mode (see note following this table) Security erase time Enhanced security erase time Master password revision code Hardware reset value (see description following this table) ATA-reserved Total number of user-addressable LBA sectors available (see Section 2.2 for related information). These words are required for drives that support the 48-bit addressing feature. Maximum value: 0000FFFFFFFFFFFFh. ATA-reserved Value xxxxH 0FFFFFFFh* 0000H xx07H 0003H 0078H 0078H 00F0H 0078H 0000H 0000H xxxxH 007EH 0000H 346BH 7D01H 4003H 34xxH 3xxxH 4003H xx3FH 0000H 0000H FFFEH xxxxH 0000H ST3400832A = 781,422,768 ST3400632A = 781,422,768 ST3300831A = 586,072,368 ST3300631A = 586,072,368 ST3250823A = 488,397,168 ST3250623A = 488,397,168 ST3200826A = 390,721,968 0000H Barracuda 7200.8 PATA Product Manual, Rev. F 31

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48

Barracuda 7200.8 PATA Product Manual, Rev. F
31
59
Number of sectors transferred during a Read Multiple or Write Multiple
command
xxxx
H
60–61
Total number of user-addressable LBA sectors available
(see Section 2.2 for related information)
*Note: The maximum value allowed in this field is: 0FFFFFFFh
(268,435,455 sectors, 137 Gbytes). Drives with capacities over 137
Gbytes will have 0FFFFFFFh in this field and the actual number of user-
addressable LBAs specified in words 100-103. This is required for
drives that support the 48-bit addressing feature.
0FFFFFFFh*
62
Retired
0000
H
63
Multiword DMA active and modes supported
(see note following this table)
xx
07
H
64
Advanced PIO modes supported (modes 3 and 4 supported)
0003
H
65
Minimum multiword DMA transfer cycle time per word (120 nsec)
0078
H
66
Recommended multiword DMA transfer cycle time per word (120 nsec)
0078
H
67
Minimum PIO cycle time without IORDY flow control (240 nsec)
00F0
H
68
Minimum PIO cycle time with IORDY flow control (120 nsec)
0078
H
69–74
ATA-reserved
0000
H
75
Queue depth
0000
H
76–79
SATA-specific
xxxx
H
80
Major version number
007E
H
81
Minor version number
0000
H
82
Command sets supported
346B
H
83
Command sets supported
7D01
H
84
Command sets support extension
4003
H
85
Command sets enabled
34
xx
H
86
Command sets enabled
3xxx
H
87
Command sets enable extension
4003
H
88
Ultra DMA support and current mode
(see note following this table)
xx
3F
H
89
Security erase time
0000
H
90
Enhanced security erase time
0000
H
92
Master password revision code
FFFE
H
93
Hardware reset value (see description following this table)
xxxx
H
95–99
ATA-reserved
0000
H
100–103
Total number of user-addressable LBA sectors available (see Section
2.2 for related information). These words are required for drives that
support the 48-bit addressing feature. Maximum value:
0000FFFFFFFFFFFFh.
ST3400832A = 781,422,768
ST3400632A = 781,422,768
ST3300831A = 586,072,368
ST3300631A = 586,072,368
ST3250823A = 488,397,168
ST3250623A = 488,397,168
ST3200826A = 390,721,968
104–127
ATA-reserved
0000
H
Word
Description
Value