Seagate ST3300655LC Cheetah 15K.6 FC Product Manual - Page 57

Interface requirements

Page 57 highlights

9.0 Interface requirements This section partially describes the interface requirements as implemented on Cheetah 15K.6 FC drives. Additional information is provided in the Fibre Channel Interface Manual (part number 100293070). 9.1 FC-AL features This section lists the Fibre Channel-specific features supported by Cheetah 15K.6 FC drives. 9.1.1 Fibre Channel link service frames Table 9 lists the link services supported by Cheetah 15K.6 FC drives. Table 9: Link services supported Type of frame Basic link service frames Basic link service reply frames Extended link service frames Extended link service reply frames Fibre Channel Services Link service Abort Sequence (ABTS) Basic_Accept (BA_ACC) Basic_Reject (BA_RJT) N_Port Login (PLOGI) Fabric Login (FLOGI) Logout (LOGO) Process Login (PRLI) Process Logout (PRLO) Read Link Status (RLS) Fabric Address Notification (FAN) Port Discovery (PDISC) Address Discovery (ADISC) Third-party Process Logout (TRPLO) Accept (ACC) Link Service Reject (LS_RJT) Register FC-4 Types (RFT_ID) Cheetah 15K.6 FC Product Manual, Rev. D 51

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66
  • 67
  • 68
  • 69
  • 70
  • 71
  • 72
  • 73
  • 74
  • 75
  • 76
  • 77
  • 78
  • 79
  • 80
  • 81
  • 82
  • 83
  • 84
  • 85
  • 86
  • 87
  • 88
  • 89
  • 90
  • 91
  • 92
  • 93
  • 94

Cheetah 15K.6 FC Product Manual, Rev. D
51
9.0
Interface requirements
This section partially describes the interface requirements as implemented on Cheetah 15K.6 FC drives. Addi-
tional information is provided in the
Fibre Channel Interface Manual
(part number 100293070).
9.1
FC-AL features
This section lists the Fibre Channel-specific features supported by Cheetah 15K.6 FC drives.
9.1.1
Fibre Channel link service frames
Table 9 lists the link services supported by Cheetah 15K.6 FC drives.
Table 9:
Link services supported
Type of frame
Link service
Basic link service frames
Abort Sequence (ABTS)
Basic link service reply frames
Basic_Accept (BA_ACC)
Basic_Reject (BA_RJT)
Extended link service frames
N_Port Login (PLOGI)
Fabric Login (FLOGI)
Logout (LOGO)
Process Login (PRLI)
Process Logout (PRLO)
Read Link Status (RLS)
Fabric Address Notification (FAN)
Port Discovery (PDISC)
Address Discovery (ADISC)
Third-party Process Logout (TRPLO)
Extended link service reply frames
Accept (ACC)
Link Service Reject (LS_RJT)
Fibre Channel Services
Register FC-4 Types (RFT_ID)