Lectromagnetic Immunity
View all Seagate ST480HM001 manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 16 highlights
2.8.6.1 Operating vibration The maximum random vibration levels that the drive may experience while meeting the performance standards specified in this document are specified below. This sp ecification does not cover connection issues that may result from testing at this level. 20-2000 Hz 11.08 Grms 2.8.6.2 Nonoperating vibration The maximum random nonoperating vibration levels that the drive may experience without incurring physical damage or degradation in performance when subsequently put into operation are specified below. 20-2000 Hz 11.08 Grms 2.9 ELECTROMAGNETIC IMMUNITY When properly installed in a representative host system, the drive operates without errors or degradation in performance when subjected to the radio frequency (RF) environments defined in the following table: Table 5 Radio frequency environments TEST DESCRIPTION PERFORMANCE REFERENCE LEVEL STANDARD Electrostatic discharge Contact, HCP, VCP: ± 4 kV; Air: ± 8 kV B Radiated RF immunity 80 to 1000 MHz, 3 V/m, A 80% AM with 1 kHz sine 900 MHz, 3 V/m, 50% pulse modulation @ 200 Hz Electrical fast transient ± 1 kV on AC mains, ± 0.5 kV on external I/O B Surge immunity ± 1 kV differential, ± 2 kV common, AC mains B Conducted RF immunity 150 kHz to 80 MHz, 3 Vrms, 80% AM with 1 kHz sine A Voltage dips, interrupts 0% open, 5 seconds C 0% short, 5 seconds C 40%, 0.10 seconds C 70%, 0.01 seconds B EN 61000-4-2: 95 EN 61000-4-3: 96 ENV 50204: 95 EN 61000-4-4: 95 EN 61000-4-5: 95 EN 61000-4-6: 97 EN 61000-4-11: 94 SEAGATE 600 SSD PRODUCT MANUAL, REV. B 12