Seagate ST500DM002 Barracuda 7200.10 PATA Product Manual - Page 41

Jumper settings - jumpers

Page 41 highlights

3.3 Jumper settings 3.3.1 Master/slave configuration The options jumper block shown in Figure 4 is used to configure the drive for operation. It is the 8-pin dual header between the interface connector and the power connector. Use the following settings to configure the drive as a master or a slave. Master or single drive. The drive is configured at the factory for a master or single drive operation with a jumper set on pins 7 and 8. Drive as slave. Remove all jumpers. Drive as master with a non-ATA-compatible slave. Use this jumper setting only if the drive does not work as a master with no jumpers installed. Options jumper block *Master or single drive Drive is slave Master with non ATAcompatible slave *Cable select 7531 8642 Figure 4 Master/slave jumper settings 3.3.2 Cable-select option Computers that use cable select determine the master and slave drives by selecting or deselecting pin 28, CSEL, on the interface bus. Master and slave drives are determined by their physical position on the cable. To enable cable select, set a jumper on pins 5 and 6 as shown in Figure 4. Refer to your computer manual to determine whether your computer supports this option. Barracuda 7200.10 PATA Product Manual, Rev. F 35

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60

Barracuda 7200.10 PATA Product Manual, Rev. F
35
3.3
Jumper settings
3.3.1
Master/slave configuration
The options jumper block shown in Figure 4 is used to configure the drive for operation. It is the 8-pin dual
header between the interface connector and the power connector. Use the following settings to configure the
drive as a master or a slave.
Master or single drive.
The drive is configured at the factory for a master or single drive operation with a
jumper set on pins 7 and 8.
Drive as slave.
Remove all jumpers.
Drive as master with a non-ATA-compatible slave.
Use this jumper setting
only
if the drive does not work as a master with no jumpers installed.
Figure 4
Master/slave jumper settings
3.3.2
Cable-select option
Computers that use cable select determine the master and slave drives by selecting or deselecting pin 28,
CSEL, on the interface bus. Master and slave drives are determined by their physical position on the cable. To
enable cable select, set a jumper on pins 5 and 6 as shown in Figure 4. Refer to your computer manual to
determine whether your computer supports this option.
Options jumper block
2
6
8
4
1
7
5
3
Drive is slave
*Master or single drive
*Cable select
Master with non ATA-
compatible slave