Identify Device command
View all Seagate ST905003N3A1AS manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 33 highlights
Command name Standby Immediate ATA-standard security commands Security Set Password Security Unlock Security Erase Prepare Security Erase Unit Security Freeze Lock Security Disable Password Command code (in hex) 94h or E0h F1h F2h F3h F4h F5h F6h 4.3.1 Identify Device command The Identify Device command (command code ECH) transfers information about the drive to the host following power up. The data is organized as a single 512-byte block of data, whose contents are shown in the table on page 27. All reserved bits or words should be set to zero. Parameters listed with an "x" are drive-specific or vary with the state of the drive. See Section 2.0 on page 3 for default parameter settings. The following commands contain drive-specific features that may not be included in the Serial ATA specification. Word 0 1 2 3 4 5 6 7-9 10-19 20 21 22 23-26 Description Configuration information: • Bit 15: 0 = ATA; 1 = ATAPI • Bit 7: removable media • Bit 6: removable controller • Bit 0: reserved Number of logical cylinders ATA-reserved Number of logical heads Retired Retired Number of logical sectors per logical track: 63 Retired Serial number: (20 ASCII characters, 0000H = none) Retired Retired Obsolete Firmware revision (8 ASCII character string, padded with blanks to end of string) Value 0C5AH 16,383 0000H 16 0000H 0000H 003FH 0000H ASCII 0000H 0400H 0000H x.xx Momentus 7200.3 SATA Product Manual, Rev. C 27