Seagate ST9100822A Momentus 4200.2 PATA Product Manual - Page 30

Description, Value

Page 30 highlights

Word 57-58 59 60-61 62 63 64 65 66 67 68 69-74 75 76-79 80 81 82 83 84 85 86 87 88 89 90 91 92 93 94 95-127 Description Current capacity in sectors Number of sectors transferred during a Read Multiple or Write Multiple command Total number of user-addressable LBA sectors available (see Section 2.2 for related information) Retired Multiword DMA active and modes supported (see note following this table) Advanced PIO modes supported (modes 3 and 4 supported) Minimum multiword DMA transfer cycle time per word (120 nsec) Recommended multiword DMA transfer cycle time per word (120 nsec) Minimum PIO cycle time without IORDY flow control (240 nsec) Minimum PIO cycle time with IORDY flow control (120 nsec) ATA-reserved Queue depth ATA-reserved Major version number Minor version number Command sets supported Command sets supported Command sets support extension Command sets enabled Command sets enabled Command sets enable extension Ultra DMA support and current mode (see note following this table) Security erase time Enhanced security erase time Advanced power management value Master password revision code Hardware reset value (see description following this table) Auto acoustic management setting ATA-reserved Value xxxxH xxxxH ST9100822A = 195,371,568 ST9808210A = 156,301,488 ST960821A = 117,210,240 ST950212A = 97,696,368 ST9402113A = 78,140,160 ST930219A = 58,605,120 0000H xx07H 0003H 0078H 0078H 00F0H 0078H 0000H 0000H 0000H 007EH 0000H 346BH 7D01H 4003H 34xxH 3xxxH 4003H xx3FH 0000H 0000H 0040H FFFEH xxxxH xxxxH 0000H 24 Momentus 4200.2 Product Manual, Rev. D

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44

24
Momentus 4200.2 Product Manual, Rev. D
57–58
Current capacity in sectors
xxxx
H
59
Number of sectors transferred during a Read Multiple or Write
Multiple command
xxxx
H
60–61
Total number of user-addressable LBA sectors available
(see Section 2.2 for related information)
ST9100822A = 195,371,568
ST9808210A = 156,301,488
ST960821A = 117,210,240
ST950212A = 97,696,368
ST9402113A = 78,140,160
ST930219A = 58,605,120
62
Retired
0000
H
63
Multiword DMA active and modes supported (see note
following this table)
xx
07
H
64
Advanced PIO modes supported (modes 3 and 4 supported)
0003
H
65
Minimum multiword DMA transfer cycle time per word (120
nsec)
0078
H
66
Recommended multiword DMA transfer cycle time per word
(120 nsec)
0078
H
67
Minimum PIO cycle time without IORDY flow control (240
nsec)
00F0
H
68
Minimum PIO cycle time with IORDY flow control (120 nsec)
0078
H
69–74
ATA-reserved
0000
H
75
Queue depth
0000
H
76–79
ATA-reserved
0000
H
80
Major version number
007E
H
81
Minor version number
0000
H
82
Command sets supported
346B
H
83
Command sets supported
7D01
H
84
Command sets support extension
4003
H
85
Command sets enabled
34
xx
H
86
Command sets enabled
3xxx
H
87
Command sets enable extension
4003
H
88
Ultra DMA support and current mode
(see note following this table)
xx
3F
H
89
Security erase time
0000
H
90
Enhanced security erase time
0000
H
91
Advanced power management value
0040
H
92
Master password revision code
FFFE
H
93
Hardware reset value (see description following this table)
xxxx
H
94
Auto acoustic management setting
xxxx
H
95–127
ATA-reserved
0000
H
Word
Description
Value