Seagate ST960815AB Momentus 5400.3 PATA Blade Server Product Manual - Page 20

Environmental specifications

Page 20 highlights

2.10 Environmental specifications 2.10.1 Ambient temperature Ambient temperature is defined as the temperature of the environment immediately surrounding the drive. Duty 50%, power-on hours (POH) of 8,760 per year (24 hours per day, 7 days per week operation). Actual drive case temperature should not exceed 45°C (113°F) within the operating ambient conditions. Above 1,000 feet (305 meters), the maximum temperature is derated linearly by 1°C every 1000 feet. Operating 0° to 40°C (32° to 104°F) Nonoperating -40° to 70°C (-40° to 158°F) 2.10.2 Temperature gradient Operating 20°C per hour (68°F per hour max), without condensation Nonoperating 30°C per hour (86°F per hour max), without condensation 2.10.3 Humidity 2.10.3.1 Relative humidity Operating 5% to 90% noncondensing (30% per hour max) Nonoperating 5% to 95% noncondensing (30% per hour max) 2.10.3.2 Wet bulb temperature Operating 30°C (86°F max) Nonoperating 38°C (100.4°F max) 2.10.4 Altitude Operating -304.8 m to 3,048 m (-1,000 ft to 10,000 ft) Nonoperating -304.8 m to 12,192 m (-1,000 ft to 40,000 ft) 14 Momentus 5400.3 PATA Blade Server Product Manual, Rev. B

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46

14
Momentus 5400.3 PATA Blade Server Product Manual, Rev. B
2.10
Environmental specifications
2.10.1
Ambient temperature
Ambient temperature is defined as the temperature of the environment immediately surrounding the drive.
Duty 50%, power-on hours (POH) of 8,760 per year (24 hours per day, 7 days per week operation). Actual
drive case temperature should not exceed
45°C (113°F) within the operating ambient conditions.
Above 1,000 feet (305 meters), the maximum temperature is derated linearly by 1°C every 1000 feet.
2.10.2
Temperature gradient
2.10.3
Humidity
2.10.3.1
Relative humidity
2.10.3.2
Wet bulb temperature
2.10.4
Altitude
Operating
0° to 40°C (32° to 104°F)
Nonoperating
–40° to 70°C (–40° to 158°F)
Operating
20°C per hour (68°F per hour max), without condensation
Nonoperating
30°C per hour (86°F per hour max), without condensation
Operating
5% to 90% noncondensing (30% per hour max)
Nonoperating
5% to 95% noncondensing (30% per hour max)
Operating
30°C (86°F max)
Nonoperating
38°C (100.4°F max)
Operating
–304.8 m to 3,048 m (–1,000 ft to 10,000 ft)
Nonoperating
–304.8 m to 12,192 m (–1,000 ft to 40,000 ft)