Seagate ST980815SB Momentus 5400.3 SATA Blade Server Product Manual - Page 18

Acoustics, Electromagnetic immunity

Page 18 highlights

2.11 Acoustics Drive acoustics are measured as overall A-weighted acoustic sound power levels (no pure tones). All measurements are consistent with ISO document 7779. Sound power measurements are taken under essentially free-field conditions over a reflecting plane. For all tests, the drive is oriented with the cover facing upward. Note. For seek mode tests, the drive is placed in seek mode only. The number of seeks per second is defined by the following equation: (Number of seeks per second = 0.4 / (average latency + average access time)) Table 4: Models 2 discs 1 disc Drive level acoustics ST9160821SB ST9120822SB ST9100828SB ST980815SB ST960815SB ST9402116SB Idle* 2.4 bels (typ) 2.6 bels (max) 2.2 bels (typ) 2.4 bels (max) Performance Seek 3.0 bels (typ) 3.2 bels (max) 2.9 bels (typ) 3.1 bels (max) *During periods of drive idle, some offline activity may occur according to the S.M.A.R.T. specification, which may increase acoustic and power to operational levels. 2.12 Electromagnetic immunity When properly installed in a representative host system, the drive operates without errors or degradation in performance when subjected to the radio frequency (RF) environments defined in the following table: Table 5: Radio frequency environments Test Electrostatic discharge Radiated RF immunity Electrical fast transient Surge immunity Conducted RF immunity Power Frequency H-field immunity Voltage dips, interrupts Description Performance level Reference standard Contact, HCP, VCP: ± 4 kV; Air: ± 8 kV B EN 61000-4-2: 95 80 to 1,000 MHz, 3 V/m, A 80% AM with 1 kHz sine 900 MHz, 3 V/m, 50% pulse modulation @ 200 Hz EN 61000-4-3: 96 ENV 50204: 95 ± 1 kV on AC mains, ± 0.5 kV on external I/ B O EN 61000-4-4: 95 ± 1 kV differential, ± 2 kV common, AC B mains EN 61000-4-5: 95 150 kHz to 80 MHz, 3 Vrms, 80% AM with A 1 kHz sine EN 61000-4-6: 97 1 A/m, 50Hz/60Hz, 3 axes A EN 61000-4-8: 97 30% Reduction for 25 cycles C >95% Reduction for 250 cycles C >95%, 0.5 cycles B EN 61000-4-11: 94 A - 1) No upset or degradation in performance beyond manufacturer's specified limits. 2) No data loss. B - 1) Unit self recovers without user intervention. 2) No data loss. C - 1) Upset OK provided that unit will function after user intervention. 12 Momentus 5400.3 SATA Blade Server Product Manual, Rev. E

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44

12
Momentus 5400.3 SATA Blade Server Product Manual, Rev. E
2.11
Acoustics
Drive acoustics are measured as overall A-weighted acoustic sound power levels (no pure tones). All mea-
surements are consistent with ISO document 7779. Sound power measurements are taken under essentially
free-field conditions over a reflecting plane. For all tests, the drive is oriented with the cover facing upward.
Note.
For seek mode tests, the drive is placed in seek mode only. The number of seeks per second is
defined by the following equation:
(Number of seeks per second = 0.4 / (average latency + average access time))
*During periods of drive idle, some offline activity may occur according to the S.M.A.R.T. specification, which may increase acoustic and
power to operational levels
.
2.12
Electromagnetic immunity
When properly installed in a representative host system, the drive operates without errors or degradation in
performance when subjected to the radio frequency (RF) environments defined in the following table:
A -
1) No upset or degradation in performance beyond manufacturer’s specified limits.
2) No data loss.
B -
1) Unit self recovers without user intervention.
2) No data loss.
C - 1) Upset OK provided that unit will function after user intervention.
Table 4:
Drive level acoustics
Models
Idle*
Performance Seek
2 discs
ST9160821SB
ST9120822SB
ST9100828SB
2.4 bels (typ)
2.6 bels (max)
3.0 bels (typ)
3.2 bels (max)
1 disc
ST980815SB
ST960815SB
ST9402116SB
2.2 bels (typ)
2.4 bels (max)
2.9 bels (typ)
3.1 bels (max)
Table 5:
Radio frequency environments
Test
Description
Performance level
Reference standard
Electrostatic discharge
Contact, HCP, VCP:
±
4
kV; Air:
±
8 kV
B
EN 61000-4-2: 95
Radiated RF immunity
80 to 1,000 MHz, 3 V/m,
80% AM with 1 kHz sine
900 MHz, 3 V/m, 50% pulse modulation @
200 Hz
A
EN 61000-4-3: 96
ENV 50204: 95
Electrical fast transient
±
1 kV on AC mains,
±
0.5 kV on external I/
O
B
EN 61000-4-4: 95
Surge immunity
±
1 kV differential,
±
2 kV common, AC
mains
B
EN 61000-4-5: 95
Conducted RF immunity
150 kHz to 80 MHz, 3 Vrms, 80% AM with
1 kHz sine
A
EN 61000-4-6: 97
Power Frequency H-field
immunity
1 A/m, 50Hz/60Hz, 3 axes
A
EN 61000-4-8: 97
Voltage dips, interrupts
30% Reduction for 25 cycles
>95% Reduction for 250 cycles
>95%, 0.5 cycles
C
C
B
EN 61000-4-11: 94