Seagate ST9808210A Momentus 4200.2 PATA Product Manual - Page 19

Acoustics, Electromagnetic immunity - install

Page 19 highlights

2.11 Acoustics Drive acoustics are measured as overall A-weighted acoustic sound power levels (no pure tones). All measurements are consistent with ISO document 7779. Sound power measurements are taken under essentially free-field conditions over a reflecting plane. For all tests, the drive is oriented with the cover facing upward. Note. For seek mode tests, the drive is placed in seek mode only. The number of seeks per second is defined by the following equation: Number of seeks per second = 0.4 / (average latency + average access time) Table 4: Drive level acoustics Acoustic mode Idle* 2.4 bels (typ) 2.6 bels (max) Quiet Seek 2.6 bels (typ) 2.8 bels (max) Performance Seek 2.9 bels (typ) 3.1 bels (max) *During periods of drive idle, some offline activity may occur, according to the S.M.A.R.T. specification, which may increase acoustic and power to operational levels. 2.12 Electromagnetic immunity When properly installed in a representative host system, the drive operates without errors or degradation in performance when subjected to the radio frequency (RF) environments defined in the following table: Table 5: Electromagnetic immunity Test Electrostatic discharge Radiated RF immunity Electrical fast transient Surge immunity Conducted RF immunity Power Frequency H-field immunity Voltage dips, interrupts Description Performance level Contact, HCP, VCP: ± 4 kV; Air: ± 8 kV B 80 to 2,000 MHz, 10 V/m, A 80% AM with 1 kHz sine 900 MHz, 3 V/m, 50% pulse modulation @ 200 Hz ± 1 kV on AC mains, ± 0.5 kV on external I/O B ± 1 kV differential, ± 2 kV common, AC mains B 150 kHz to 80 MHz, 3 Vrms, 80% AM with 1 A kHz sine 1 A/m, 50Hz/60Hz, 3 axes A 30% Reduction for 25 cycles C >95% Reduction for 250 cycles C >95%, 0.5 cycles B Reference standard EN 61000-4-2: 95 EN 61000-4-3: 96 ENV 50204: 95 EN 61000-4-4: 95 EN 61000-4-5: 95 EN 61000-4-6: 97 EN 61000-4-8: 97 EN 61000-4-11: 94 A - 1) No upset or degradation in performance beyond manufacturer's specified limits. 2) No data loss. B - 1) Unit self recovers without user intervention. 2) No data loss. C - 1) Upset OK provided that unit will function after user intervention. Momentus 4200.2 Product Manual, Rev. D 13

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44

Momentus 4200.2 Product Manual, Rev. D
13
2.11
Acoustics
Drive acoustics are measured as overall A-weighted acoustic sound power levels (no pure tones). All mea-
surements are consistent with ISO document 7779. Sound power measurements are taken under essentially
free-field conditions over a reflecting plane. For all tests, the drive is oriented with the cover facing upward.
Note.
For seek mode tests, the drive is placed in seek mode only. The number of seeks per second is
defined by the following equation:
Number of seeks per second = 0.4 / (average latency + average access time)
*During periods of drive idle, some offline activity may occur, according to the S.M.A.R.T. specification, which may increase acoustic and
power to operational levels
.
2.12
Electromagnetic immunity
When properly installed in a representative host system, the drive operates without errors or degradation in
performance when subjected to the radio frequency (RF) environments defined in the following table:
A - 1) No upset or degradation in performance beyond manufacturer’s specified limits.
2) No data loss.
B - 1) Unit self recovers without user intervention.
2) No data loss.
C - 1) Upset OK provided that unit will function after user intervention.
Table 4:
Drive level acoustics
Acoustic mode
Idle*
Quiet Seek
Performance Seek
2.4 bels (typ)
2.6 bels (max)
2.6 bels (typ)
2.8 bels (max)
2.9 bels (typ)
3.1 bels (max)
Table 5:
Electromagnetic immunity
Test
Description
Performance
level
Reference
standard
Electrostatic discharge
Contact, HCP, VCP: ± 4
kV; Air:
± 8 kV
B
EN 61000-4-2: 95
Radiated RF immunity
80 to 2,000 MHz, 10 V/m,
80% AM with 1 kHz sine
900 MHz, 3 V/m, 50% pulse modulation @ 200
Hz
A
EN 61000-4-3: 96
ENV 50204: 95
Electrical fast transient
± 1 kV on AC mains, ± 0.5 kV on external I/O
B
EN 61000-4-4: 95
Surge immunity
± 1 kV differential, ± 2 kV common, AC mains
B
EN 61000-4-5: 95
Conducted RF immunity
150 kHz to 80 MHz, 3 Vrms, 80% AM with 1
kHz sine
A
EN 61000-4-6: 97
Power Frequency H-field
immunity
1 A/m, 50Hz/60Hz, 3 axes
A
EN 61000-4-8: 97
Voltage dips, interrupts
30% Reduction for 25 cycles
>95% Reduction for 250 cycles
>95%, 0.5 cycles
C
C
B
EN 61000-4-11: 94