Seiko S351 Manual - Page 6

To Preserve The Quality Of Your Stopwatch, Liquid Crystal Panel

Page 6 highlights

3 After the starting time setting is completed, press buttonɹB to start the stopwatch. For the stopwatch operation, refer to the stopwatch operation explained above. A B Notes: ɾWhen the stopwatch is stopped, "STOP" and " ˅" marks are displayed. ɾWhile the stopwatch is counting, " ˅" is not displayed. ɾWhile the split time is measured, "SPLIT" and " ˅" are displayed. If button Bɹis pressed while the ɹsplit time is measured, the measurement is stopped and the total elapsed time is displayed in place ɹof the split time. ɾA negative calculation result obtained in the time calculation mode can be set as the starting time ɹwith the recall key. If button ɹ B is pressed to start the stopwatch, however, the error mark "Error" is ɹdisplayed and the stopwatch will not start counting. Press the clear/clear entry key to reset the digits ɹto "0:00˄00˅" and then enter a proper starting time. ɾThe set staring time is not stored in memoty, and it will be canceled once the stopwatch is started. ɾThe arithmetic operation keys [ʴ] [ʵ] and [ʹ] do not work in the stopwatch mode. ˙NOTES ON THE BATTERIES [Battery for the stopwatch] BATTERY LIFE A new normal battery will last approximately three years. ˎIf the timer is used more than 10 times a day, the battery life may be less than ɹthe specified period.  ˎThe battery in your watch may run down in less than the specified period ɹafter the date ofpurchase, as it is a monitor battery inserted at the factory ɹto check the functions and performance of the watch. ˎThe battery in your watch will therefore be replaced with a new one only at ɹcost even if it runs down within the guarantee period. BATTERY LIFE INDICATOR When flashing "ɹ" mark appears in the upper left of the display, replace the battery with a new one as soon as possible. Otherwise, the watch may stop operating in 2 to 3 days. We suggest that you have the battery replaced by a retailer from whom your watch was purchased or a SEIKO dealer. ˎEven though the flashing "ɹ" mark is displayed, time accuracy is not ɹaffected.  BATTERY CHANGE ઒ When replacing the battery, be sure to take your watch to the retailer from whom your watch was purchased or an AUTHORIZED SEIKO DEALER , and specify the " SEIKO genuine SB battery ". If an old battery is kept inside the watch for a long time, electrolyte leakage may occur and a malfunction may be caused. Be sure to replace the battery as soon as it runs down to prevent any possible malfunction. ˎWhen a battery is taken out of a watch, it must be kept at a ɹplace beyond the reach of an infant. In case it is swallowed ɹby an infant, consult a doctor immediately. ˙CARE OF YOUR STOPWATCH WATER RESISTANT ANTI-SHOCK ANTI-MAGNETIC TEMPERATURE Your watch is designed to work with stable accuracy between normal temperature range of 5°C and 35°C . Being equipped with the number entry and other keys as used in calculators, your watch is not water resistant according to the water resistance standard for watches. It can withstand, however, the accidental contact with splashes of water or rain. If the watch is wet, wipe it thoroughly dry with a soft dry cloth or the like. Light activities will not affect yourwatch, but be careful not to drop your watch or hit it against hard surfaces, as this way cause damage. Magnetism will not affect the watch ˎAs a small amount of moisture is included inside the stopwatch , the inner surface of the glass may be temporarily blurred if the atmospheric temperature is lower than that inside the stopwatch . This does not adversely affect it . However , if the blur persists for a long time, we suggest that you have the stopwatch checked by the retailer from whom it was purchased. Do not leave your watch in direct sunlight or very high temperatures for a long time. • The display may become black, but this condition will be corrected when the watch returns to normal temperature . Do not leave the watch in a very low temperature, as this may cause : 1) A slight time loss or gain. 2) The change of digits to become slow (with accuracy remaining normal.) The adove conditions will be corrected when the watch returns to normal temperature. ˎIf the watch is left in temperatures over 60ˆ or below-10ˆfor a long time,the watch maystop operating, battery leakage may be occurred, or the battery life may be shortened. CHEMICALS As plastic materials are used for the watch case, be careful not to expose the watch to solvents ( such as alcohol and gasoline), cosmetic spray, detergent, adhesives or paints, as the case, bracelet, etc. will be discolored, deteriorate or deform through the chemical action. ˙-*26*%$3:45"-1"/&-˙5013&4&37&5)&26"-*5:0':06345018"5$) STATIC ELECTRICITY The IC (Integrated Circuit) used in your watch will be affected by static electricity, which may disturb the display. Keep your watch away from close contact with suchobjects as TV screens which emit strong static electricity. After about 7 years of use digital display panel will decrease in contrast, becoming difficult to read. Have the panel replaced with a new one by the retailer from whom your watch was purchased or an AUTHORIZED SEIKO DEALER. The panel will be replaced at cost. CHECK It is recommended that the stopwatch be checked every time the battery for the stopwatch is replaced with a new one or once every 2 to 3 years . We suggest that you have your watch checked by a SEIKO DEALER when the battery is replaced, for oil condition, battery electrolyte leakage or damage due to water or sweat. After checking the watch, adjustment or repair may be required. ˎBe sure to have the gasket and push-pin replaced with new ones by a SEIKO DEALER after the watch is adjusted or repaired. ˎSpecify "SEIKO GENUINE PARTS" when replacing the parts.

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7

After the starting time setting is completed, press button
to start the stopwatch. For the stopwatch
operation, refer to the stopwatch operation explained above.
Notes:
When the stopwatch is stopped, “STOP” and “
” marks are displayed.
While the stopwatch is counting, “
” is not displayed.
While
the
split time
is
measured,
“SPLIT”
and “
” are displayed. If button
is pressed while the
split time is measured,
the measurement is stopped and the total elapsed time is displayed in place
of the split time.
A negative
calculation
result
obtained
in
the time calculation mode can be set as the starting time
with the recall key.
If button
is pressed to start the
stopwatch,
however,
the error mark “Error” is
displayed and the stopwatch will not start counting. Press the clear/clear entry key to reset the digits
to “0:00
00
” and then enter a proper starting time.
The set staring time is not stored in memoty, and it will be canceled once the stopwatch is started.
The arithmetic operation keys [
] [
] and [
] do not work in the stopwatch mode.
A
B
3
B
B
B
NOTES ON THE BATTERIES
When
flashing
” mark
appears in the upper left of the display,
replace the battery with a new one as soon as possible. Otherwise,
the watch
may stop operating in 2 to 3 days.
We suggest that you
have the battery
replaced by a retailer from whom your watch was
purchased or a SEIKO dealer.
Even
though
the
flashing
mark
is
displayed,
time
accuracy is not
affected.
BATTERY LIFE INDICATOR
BATTERY LIFE
[Battery for the stopwatch]
A new normal battery will last approximately three years.
If the timer is used more than 10 times a day, the battery life may be less than
the specified period.
The battery in your watch may run down in less than the specified period
after the date of
purchase, as it is a monitor battery inserted at the factory
to check the functions and performance of the watch.
The battery in your watch will therefore be replaced with a new one only at
cost even if it runs down within the guarantee period.
When replacing the battery, be sure to
take
your
watch
to
the
retailer
from
whom
your watch
was
purchased
or an
AUTHORIZED
SEIKO
DEALER , and
specify the
" SEIKO
genuine
SB
battery ".
If
an
old
battery
is
kept
inside
the
watch
for
a
long
time,
electrolyte
leakage may occur
and
a
malfunction
may
be
caused.
Be
sure
to
replace
the
battery
as
soon
as
it runs
down to prevent any possible malfunction.
When a battery is taken out of a watch, it must be kept at a
place beyond the reach of an infant. In case it is swallowed
by an infant, consult a doctor immediately.
BATTERY CHANGE
CARE OF YOUR STOPWATCH
Being equipped with the
number entry and other
keys as used in calculators,
your watch is not water
resistant according to the
water resistance
standard
for watches. It can with-
stand,
however,
the
accidental
contact
with
splashes of water or rain. If
the watch is wet, wipe it
thoroughly dry with a soft
dry cloth or the like.
WATER RESISTANT
ANTI-SHOCK
Light activities will not
affect your
watch, but
be careful not to drop
your
watch
or
hit
it
against hard surfaces,
as
this
way
cause
damage.
TEMPERATURE
Your
watch
is
designed
to
work
with
stable accuracy
between normal temperature range of 5°C
and
35°C .
Do
not
leave your watch
in
direct
sunlight
or
very
high
temperatures for a long time.
• The
display
may
become
black, but this condition will
be
corrected
when
the
watch
returns
to
normal
temperature .
Do not leave the watch in a very low
temperature,
as this may cause :
1) A slight time loss or gain.
2) The change of digits to become
slow
(with accuracy remaining normal.)
The adove conditions will be corrected when the watch returns to normal
temperature.
If the watch is left in temperatures over 60
or below-10
for a long time,the
watch may
stop operating, battery leakage may be occurred, or the battery
life may be shortened.
ANTI-MAGNETIC
Magnetism will not affect
the
watch
As
a
small
amount
of
moisture
is
included
inside
the
stopwatch
,
the
inner
surface
of
the
glass
may
be
temporarily
blurred
if
the
atmospheric
temperature
is
long time, we suggest that you have the stopwatch checked
by the retailer from whom it was purchased.
lower
than
that
inside
the
stopwatch .
This
does
not
adversely
affect
it .
However ,
if
the
blur
persists
for a
TO PRESERVE THE QUALITY OF YOUR STOPWATCH
LIQUID CRYSTAL PANEL
CHECK
Be sure to have the gasket and push-pin replaced with
Specify
“SEIKO
GENUINE
PARTS”
After
checking
the
watch, adjustment or repair may
be
required.
new ones
by
a
SEIKO DEALER
after
the watch
is
adjusted or repaired.
when
replacing
the
parts.
It is recommended that the stopwatch be checked every
time
the
battery
for
the stopwatch
is
replaced
with
a
new one
or
once
every 2 to 3 years .
We suggest
that
you
have
your
watch
checked
by
a
SEIKO
DEALER
when the
battery
is
replaced,
for oil
condition,
battery
electrolyte leakage or damage due to water or sweat.
STATIC ELECTRICITY
CHEMICALS
The IC (Integrated
Circuit)
used in your watch will
be
affected by static electricity,
which may disturb the display.
Keep your watch
away
from
close
contact
with
suchobjects
as TV screens which emit strong
static electricity.
As
plastic
materials are
used for the watch case,
be careful not to expose
the
watch
to
solvents
( such as alcohol and
gasoline),
cosmetic
spray, detergent, adhe-
sives or
paints, as
the
case, bracelet, etc. will
be discolored, deterio-
rate or deform through
the
chemical action.
After about 7 years of
use digital display
panel will decrease in contrast, becoming
difficult to read.
Have the panel replaced
with a new one by the retailer from whom
your watch was purchased or an
AUTHORIZED SEIKO DEALER.
The