Sennheiser EW 100 G4-865 Product Specification ew 100 G4-835-S/845-S/865-S - Page 3

SKM 100 G4-S, MMD 835-1, MMD 845-1, MME 865-1 - 835 s b

Page 3 highlights

PRODUCT SPECIFICATION 3/7 evolution wireless G4 ew 100 G4-835-S | ew 100 G4-845-S | ew 100 G4-865-S | Vocal Set SPECIFICATIONS SKM 100 G4-S RF characteristics Modulation Frequency ranges Transmission frequencies Wideband FM A1: 470 - 516 MHz A: 516 - 558 MHz A10: 516 - 558 MHz AS: 520 - 558 MHz G: 566 - 608 MHz GB: 606 - 648 MHz B: 626 - 668 MHz B10: 626 - 668 MHz C: 734 - 776 MHz D: 780 - 822 MHz JB: 806 - 810 MHz E: 823 - 865 MHz K+: 925 - 937,5 MHz 1G8: 1785 - 1800 MHz Max. 1680 receiving frequencies, adjustable in 25 kHz steps 20 frequency banks, each with up to 12 factory-preset channels, no intermodulation Switching bandwidth Nominal/peak deviation Frequency stability RF output power at 50 Ω Pilot tone squelch 1 frequency bank with up to 12 programmable channels up to 42 MHz ±24 kHz / ±48 kHz ≤ ±15 ppm Max. 30 mW Can be switched off AF characteristics Compander system AF frequency response Signal-to-noise ratio (1 mV, peak deviation) Total harmonic distortion (THD) Max. input voltage Input impedance Input capacitance Setting range for input sensitivity Sennheiser HDX 80 - 18,000 Hz ≥ 110 dBA ≤ 0.9 % 3 Veff 40 kΩ Switchable 48 dB, adjustable in 6 dB steps Overall device Temperature range Power supply Nominal voltage Current consumption Operating time Dimensions Weight (incl. batteries) -10 °C to +55 °C 2 AA batteries, 1.5 V or BA 2015 accupack 3 V battery / 2.4 V rechargeable battery at nominal voltage: typ. 180 mA with transmitter switched off: ≤ 25 µA Typically 8 h Approx. Ø 50 x 265 mm approx. 450 g SPECIFICATIONS MMD 835-1 Transducer principle Sensitivity Sound pressure level Pick-up pattern MMD 845-1 Transducer principle Sensitivity Sound pressure level Pick-up pattern dynamic 2.1 mV/Pa 154 dB SPL cardioid dynamic 1.6 mV/Pa 154 dB SPL supercardioid MME 865-1 Transducer principle Sensitivity Sound pressure level Pick-up pattern pre-polarized condensor microphone 1.6 mV/Pa 152 dB SPL supercardioid

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7

PRODUCT SPECIFICATION
evolution wireless G4
ew 100 G4-835-S | ew 100 G4-845-S |
ew 100 G4-865-S | Vocal Set
3/7
SPECIFICATIONS
SKM 100 G4-S
RF characteristics
Modulation
Wideband FM
Frequency ranges
A1: 470 - 516 MHz
A: 516 - 558 MHz
A10: 516 - 558 MHz
AS: 520 - 558 MHz
G: 566 - 608 MHz
GB: 606 - 648 MHz
B: 626 - 668 MHz
B10: 626 - 668 MHz
C: 734 - 776 MHz
D: 780 - 822 MHz
JB: 806 - 810 MHz
E: 823 - 865 MHz
K+: 925 - 937,5 MHz
1G8: 1785 - 1800 MHz
Transmission frequencies
Max. 1680 receiving
frequencies, adjustable in
25
 
kHz steps
20 frequency banks, each
with up to 12 factory-preset
channels, no intermodula-
tion
1 frequency bank with up to
12 programmable channels
Switching bandwidth
up to 42 MHz
Nominal/peak deviation
±24 kHz / ±48 kHz
Frequency stability
≤ ±15 ppm
RF output power at 50 Ω
Max. 30 mW
Pilot tone squelch
Can be switched off
AF characteristics
Compander system
Sennheiser HDX
AF frequency response
80 – 18,000 Hz
Signal-to-noise ratio (1 mV,
peak deviation)
≥ 110 dBA
Total harmonic distortion
(THD)
≤ 0.9 %
Max. input voltage
3 V
eff
Input impedance
40 kΩ
Input capacitance
Switchable
Setting range for input
sensitivity
48 dB,
adjustable in 6 dB steps
Overall device
Temperature range
-10 °C to +55 °C
Power supply
2 AA batteries, 1.5 V or
BA 2015 accupack
Nominal voltage
3 V battery /
2.4 V rechargeable battery
Current consumption
at nominal voltage:
typ. 180 mA
with transmitter switched
off: ≤ 25 μA
Operating time
Typically 8 h
Dimensions
Approx. Ø 50 x 265 mm
Weight (incl. batteries)
approx. 450 g
SPECIFICATIONS
MMD 835-1
Transducer principle
dynamic
Sensitivity
2.1 mV/Pa
Sound pressure level
154 dB SPL
Pick-up pattern
cardioid
MMD 845-1
Transducer principle
dynamic
Sensitivity
1.6 mV/Pa
Sound pressure level
154 dB SPL
Pick-up pattern
supercardioid
MME 865-1
Transducer principle
pre-polarized condensor
microphone
Sensitivity
1.6 mV/Pa
Sound pressure level
152 dB SPL
Pick-up pattern