Sennheiser SL DW Handheld 865 Instruction manual SpeechLine Digital Wireless P - Page 111
All LEDs are flashing red, A channel's LED is green
View all Sennheiser SL DW Handheld 865 manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 111 highlights
SL MCR DW All LEDs are green ▷ After the power supply is switched on: The device is starting (approx. 20 seconds). Afterwards the status information is displayed. All four LEDs light up green during startup even with the two-channel variant SL MCR 2 DW. ▷ During operation: A radio link to the transmitters has been established for all channels. All LEDs are flashing green ▷ The Identify function for the entire device was initiated in the Control Cockpit. All LEDs are yellow ▷ All received transmitters have been muted with the MUTE switch. All LEDs are flashing yellow ▷ The device is performing a firmware update. See „Updating the firmware". All LEDs are red ▷ There is no radio link to a transmitter for any of the channels. All LEDs are flashing red ▷ A device error has occurred. Details are shown in the Control Cockpit. or ▷ An error occurred while updating the device firmware. Details are shown in the Control Cockpit. A channel's LED is green ▷ A radio link to the transmitter is established. A channel's LED is flashing green ▷ The Identify function for this channel was initiated in the Control Cockpit. The LED of the received transmitter also flashes. 110