Sharp EC-S5170 ECS5170 Operation Manual

Sharp EC-S5170 Manual

Sharp EC-S5170 manual content summary:

  • Sharp EC-S5170 | ECS5170 Operation Manual - Page 1
    MODELS EC-S5170 EC-T5180 EC-T5180A EC-T5180B OPERATION MANUAL VACUUM CLEANER CONTENTS PAGE • IMPORTANT SAFETY INSTRUCTIONS .... 2 • PARTS IDENTIFICATION 4 • SPECIFICATIONS 4 • OPERATING INSTRUCTIONS 6 • MAINTENANCE INSTRUCTIONS 10 • REPLACEMENT INSTRUCTIONS 15 • BEFORE REQUESTING SERVICE
  • Sharp EC-S5170 | ECS5170 Operation Manual - Page 2
    the following: Read all instructions carefully before using this vacuum a toy. 4 Use only as described in this manual. Use only manufacturers recommended attachments. 5 Never operate water. Return the vacuum cleaner to a Sharp Authorized Servicer in the United States for examination and repair
  • Sharp EC-S5170 | ECS5170 Operation Manual - Page 3
    25 Use the carrying handle on the back of the body to carry this vacuum cleaner. Before servicing this vacuum cleaner, allow all parts to cool. CAUTION: To reduce the risk of electric shock, the filters regularly. SAVE THESE INSTRUCTIONS This vacuum cleaner is intended for household use only. 3
  • Sharp EC-S5170 | ECS5170 Operation Manual - Page 4
    Hose Rug / Floor Selector Pedal Head Cover Power Control (EC-T5180 series only) Dirt Compartment Max Fill Line Head Light Handle Release Bumper Extra Hose (EC-T5180 series only) SPECIFICATIONS FEATURES MODEL EC-S5170 EC-T5180 EC-T5180A EC-T5180B INPUT (Amp) 12.0 12.0 4 HEAD LIGHT YES POWER
  • Sharp EC-S5170 | ECS5170 Operation Manual - Page 5
    REAR Dirt Compartment Handle (Upper) Dirt Compartment Handle (Lower) Dirt Compartment Max Fill Line Exhaust Filter (Inside) Bumper Cord Storage Hook Carrying Handle Power Cord Upholstery Tool with Detachable Brush Name Plate ON/OFF Switch WARNING: Operate vacuum cleaner only at the voltage
  • Sharp EC-S5170 | ECS5170 Operation Manual - Page 6
    OPERATING INSTRUCTIONS HOW TO ATTACH THE HANDLE TO VACUUM CLEANER 1 First remove the handle screw. Then slide the base of the handle to the body of the
  • Sharp EC-S5170 | ECS5170 Operation Manual - Page 7
    HOW TO RELEASE THE HANDLE Place foot on the left side of the nozzle head and pull the handle to release.(Fig.6) Upright Position Push the handle forward so it is locked in upright position. In this position, agitator brush stop autmatically by "Agitator Safety Mechanism". NOTE: Agitator Safety
  • Sharp EC-S5170 | ECS5170 Operation Manual - Page 8
    OPERATING INSTRUCTIONS ON/OFF SWITCH At the back lower left of vacuum cleaner. The ON/OFF switch is located. (Fig.9) ON/OFF Switch Fig.9 POWER CONTROL SWITCH (EC-T5180 series only) A slide switch allows selection of cleaning power from low "L" to high "H". To increase the suction power; slide
  • Sharp EC-S5170 | ECS5170 Operation Manual - Page 9
    HOW TO USE THE ON BOARD TOOLS Fig.11 CREVICE TOOL For door tracks, narrow spots, etc.(Fig.12) EXTENSION WANDS For reaching ceilings, curtains, etc.(Fig.13) Combine these wands at the end of suction hose. (Fig.14-1) When connecting two wands, match the illustrated mark to each other.(Fig.14-2)
  • Sharp EC-S5170 | ECS5170 Operation Manual - Page 10
    MAINTENANCE INSTRUCTIONS Unplug this vacuum cleaner from the electrical outlet before servicing. HOW TO REMOVE AND REPLACE DIRT COMPARTMENT DIRT COMPARTMENT The dirt compartment assembly consists of the following parts: Dirt Compartment Release Upper Handle Filter Compartment
  • Sharp EC-S5170 | ECS5170 Operation Manual - Page 11
    Projection Slot Fig.23 STEP 2 6 Align the rectangular groove to the guide of vacuum cleaner then push to snap into place. (Fig.24) Rectangular Mark Groove Also marks are on Dust Compartment and Base. STEP 1 Guide Mark Fig.24 CAUTION: Do not use chemicals, bleach or hot water to
  • Sharp EC-S5170 | ECS5170 Operation Manual - Page 12
    MAINTENANCE INSTRUCTIONS HOW TO CLEAN THE NET FILTER ASSEMBLY 1 Slide net filter assembly out of dirt compartment. 2 Unscrew the filter element from the assembly. (Fig.25) 3 Wipe
  • Sharp EC-S5170 | ECS5170 Operation Manual - Page 13
    WHEN YOU FOUND ANY OBSTACLES IN THE HEAD COVER OR FRONT CHANNEL If you find some obstacles such as hair, paper slip, are caught inside the head cover or front channel, please try to remove with suction hose of this vacuum cleaner. (Fig.27) If this is not enough cleaning, please use some wooden
  • Sharp EC-S5170 | ECS5170 Operation Manual - Page 14
    cover is secured by two screws from the bottom side. 1 Remove the bottom plate, following the instructions on page 13. Top Tab Head Cover 2 Remove the agitator assembly and the belt, following the instructions on page17. Fig.30 3 Unscrew two screws at the nozzle head. (Fig.31) 4 Lift the top
  • Sharp EC-S5170 | ECS5170 Operation Manual - Page 15
    , the main filter can be used throughout the life of the vacuum cleaner. If you chose to replace main filter, please refer to the maintenance instructions on page 12 which explain how to remove and replace filter. Filter Cover Filter Clamp Top Handle Grip Latch Portion Main Filter Fig.36 15
  • Sharp EC-S5170 | ECS5170 Operation Manual - Page 16
    INSTRUCTIONS HOW TO MAINTAIN OR REPLACE THE EXHAUST FILTERS The exhaust filter consists of an electrostatic HEPA Type filter. (EC-S5170) HEPA Filter (EC-T5180 series) The HEPA Type filter should be replaced at least every 10 months to maintain efficient filtration. (EC-S5170) HEPA Filter(EC
  • Sharp EC-S5170 | ECS5170 Operation Manual - Page 17
    agitator assembly fit in the groove of the nozzle head. (Fig. 43) Be sure to install the new flat belt into the belt guide properly. (Fig. 43) Motor Shaft Idler Pulley Flat Belt Main Pulley Arrow (To insert the agitator assembly into the nozzle head, follow the Arrow direction as indicated.) Fig
  • Sharp EC-S5170 | ECS5170 Operation Manual - Page 18
    the plug properly into the outlet. Replace the flat belt or install it properly. Suction power is weak or request service if the problem still persists or if the problem is not defined in the Troubleshooting Chart. service problems, warranty information, missing items and other assistance: Sharp
  • Sharp EC-S5170 | ECS5170 Operation Manual - Page 19
    1-800-642-2122, or visit Sharp's web site at www.sharp-usa.com. ITEM 1 2 3 4 PARTS DESCRIPTION FLAT BELT EXHAUST FILTER (EC-S5170) EXHAUST FILTER (EC-T5180 series) MAIN FILTER PART NUMBER EC-02BU3 (2 PCS IN 1 PACK ) EC-01MU14 (HEPA Type) EC-01MU13 (HEPA Filter) EC-01MU12 For other parts, please
  • Sharp EC-S5170 | ECS5170 Operation Manual - Page 20
    Service: EC-S5170, EC-T5180,T5180A. or T5180B Home Use Vacuum Cleaner. (Be sure to have this information available when you need service for your product.) One (1) year parts and labor. Appearance items of the product, accessories, filters, or any printed materials. At a Sharp Authorized Servicer
  • Sharp EC-S5170 | ECS5170 Operation Manual - Page 21
    Utilice el aparato sólo para su uso especifico como se describe en este manual. Utilice sólo los accesorios recomendados por el fabricante. 5 No opere agua. Retorne el aparato a un distribuidor o tienda de servicio autorizado de Sharp en los Estados Unidos para su examinación y reparación. 6 No tire
  • Sharp EC-S5170 | ECS5170 Operation Manual - Page 22
    ADICIONAL POR ESCRITO: Por problemas de funcionamiento, información acerca de la garantía, unidades incompletas u otro tipo de consultas. Sharp Electronics Corporation Customer Assistance Center 1300 Naperville Drive Romeoville, IL 60446-1091 Cuando nos llame o escriba suministrenos la siguiente
  • Sharp EC-S5170 | ECS5170 Operation Manual - Page 23
    ARTICULO NUMERO DE PARTE CORREA PLANA EC-02BU3 (2 Piezas en 1 Paquete ) FILTRO DE RESCARGA (EC-S5170) EC-01MU14 ( ) FILTRO DE RESCARGA (EC-T5180 serie) EC-01MU13 ( ) FILTRO PRINCIPAL EC-01MU12 Para Partes, por favor contacte a su distribuidor Sharp mas cercano, si su distribuidor no
  • Sharp EC-S5170 | ECS5170 Operation Manual - Page 24
    causados por cualquiera que no sea un reparador de servicio autorizado. Sharp no se responsabilizará de ninguna forma de los daños econónmicos hubiera): Donde obtener el servicio: Que hacer para obtener el servicio: EC-S5170,EC-T5180,T5180A.o T5180B Aspiradora para uso en el hogar. (Tenga
  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24

OPERATION MANUAL
VACUUM CLEANER
EC-S5170
EC-T5180
EC-T5180A
EC-T5180B
MODELS
• IMPORTANT SAFETY
INSTRUCTIONS
....
2
• PARTS
IDENTIFICATION
...........................
4
• SPECIFICATIONS
........................................
4
• OPERATING
INSTRUCTIONS
...................
6
• MAINTENANCE
INSTRUCTIONS
..............
10
• REPLACEMENT
INSTRUCTIONS
.............
15
• BEFORE
REQUESTING
SERVICE
...........
18
• DESCRIPTION
OF
ACCESSORIES
..........
19
• CONSUMER LIMITED
WARRANTY
..........
20
• SPANISH DIGEST
.......................................
21
CONTENTS
PAGE
Thank you very much for buying
SHARP
Before using your SHARP vacuum cleaner, please
read this operation manual carefully to obtain
the
optimum performance from your vacuum cleaner.