Sharp KB-6015KKC Installation Manual - Page 3

Microwave Drawer Measurements, Anti-tip Block

Page 3 highlights

INSTALLATION MANUAL MICROWAVE DRAWER MEASUREMENTS 84" wall cabinet electrical outlet location 5" (6") 2x4 AntiTip block 3 1/2" 36" countertop height 4" 28 7/16" opening allow 3/4" overlap 23 1/2" min depth allow 3/4" overlap allow 1/4" overlap 14 3/4" opening 14 3/4" to bottom of Anti-Tip block allow 7/16" overlap floor must support 100 lbs. optional wall oven cutout illustrated in sketch 19" to top of floor electrical outlet location 5" 4" 28 7/16" opening allow 3/4" overlap 23 1/2" min depth allow 3/4" overlap 30" cabinet min. Figure 2 (6") 2x4 Anti-Tip block 3 1/2" 2" minimum allow 1/4" overlap 14 3/4" to bottom of Anti-Tip block 14 3/4" opening allow 7/16" overlap floor must support 100 lbs. *19" to top of floor (recommended) Figure 1 30" * cabinet min. NOTE: Open Top Cabinet illustrated Figures 1 and 2 contain many Microwave Drawer measurements for reference when planning the drawerʼs location. 4 11/16" 2" 28 1/8" 15" 15" auto drawer opening 14 19/32" 23 3/8" Figure 3 1 13/16" door thickness 30" ANTI-TIP BLOCK (6") 5" Figure 4 2x4 AntiTip block NORMAL INSTALLATION STEPS ANTI-TIP BLOCK INSTALLATION INSTRUCTIONS To reduce the risk of tipping of the drawer, the Anti-Tip block must be properly installed located 14 3/4-inches above the floor on which the Microwave Drawer will sit. The 6-inch 2 x 4 Anti-Tip block must be provided by the installer. See Figures 1, 2 and 4. The Anti-Tip block prevents serious injury that might result from spilled hot liquids. If the Microwave Drawer is ever moved to a different location, the Anti-Tip block must also be moved and installed. When installed to the wall, make sure that the screws completely penetrate the dry wall and are secured in wood or metal so that the block is totally stable. When fastening, be sure that the screws do not penetrate electrical wiring or plumbing. 3

  • 1
  • 2
  • 3
  • 4

3
28 1/8"
23 3/8"
14 19/32"
1 13/16"
door thickness
15"
30"
15"
auto drawer
opening
2"
4 11/16"
36"
countertop
height
30"
*
cabinet min.
28 7/16"
opening
14 3/4"
opening
allow 1/4"
overlap
allow 7/16"
overlap
allow 3/4"
overlap
allow 3/4"
overlap
19"
to top of floor
4"
5"
electrical outlet
location
2x4 Anti-
Tip block
floor must
support
100 lbs.
NOTE: Open Top
Cabinet illustrated
14 3/4"
to bottom
of Anti-Tip
block
3 1/2"
(6")
23 1/2"
min depth
84"
wall
cabinet
30"
cabinet min.
28 7/16"
opening
14 3/4"
opening
allow 1/4"
overlap
allow 7/16"
overlap
allow 3/4"
overlap
allow 3/4"
overlap
*19"
to top of floor
(recommended)
4"
5"
2" minimum
electrical outlet
location
2x4 Anti-Tip block
optional wall oven
cutout illustrated
in sketch
floor must
support 100 lbs.
14 3/4"
to bottom
of Anti-Tip
block
3 1/2"
(6")
23 1/2"
min depth
INSTALLATION MANUAL
Figure 2
Figure 1
Figures 1 and 2 contain many Microwave Drawer measurements
for reference when planning the drawerʼs location.
MICROWAVE DRAWER MEASUREMENTS
ANTI-TIP BLOCK
2x4 Anti-
Tip block
(6")
Figure 4
Figure 3
NORMAL INSTALLATION STEPS
ANTI-TIP BLOCK INSTALLATION INSTRUCTIONS
To reduce the risk of tipping of the drawer, the Anti-Tip block
must be properly installed located 14 3/4-inches above the floor on
which the Microwave Drawer will sit. The 6-inch 2 x 4 Anti-Tip
block must be provided by the installer. See Figures 1, 2 and 4.
The Anti-Tip block prevents serious injury that might result from
spilled hot liquids.
If the Microwave Drawer is ever moved to a different location, the
Anti-Tip block must also be moved and installed. When installed
to the wall, make sure that the screws completely penetrate the
dry wall and are secured in wood or metal so that the block is
totally stable. When fastening, be sure that the screws do not
penetrate electrical wiring or plumbing.