Sharp KB3401LK KB-3401LS , KB-3401LK , KB-3401LW Installation Instructions - Page 6
Anti-tip
UPC - 074000616172
View all Sharp KB3401LK manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 6 highlights
Installation Manual Anti-Tip NORMAL INSTALLATION STEPS Anti-Tip bracket Installation Instructions Important Safety Warning To reduce the risk of tipping of the range, the range must be secured to the floor by properly installed Anti-Tip bracket and screws packed with the range. Failure to install the Anti-Tip bracket will allow the range to tip over if excessive weight is placed on an open door or if a child climbs upon it. Serious injury might result from spilled hot liquids or from the range itself. If range is ever moved to a different location, the Anti-Tip bracket must also be moved and installed with the range. Instructions are provided for installation in wood or cement fastened to either the floor or wall. When installed to the wall, make sure that screws completely penetrate dry wall and are secured in wood or metal. When fastening to the floor or wall, be sure that screws do not penetrate electrical wiring or plumbing. 1 Locate the bracket - Using the Template The bracket may be located on either the left or right side of the range. Refer to figure 12b to locate the bracket if template is not available. Mark the floor or wall where left or right side of the range will be located. If rear of range is against the wall or no further than 1 1/4-inches from wall when installed, you may use the wall or floor mount method. See Figure 13. If molding is installed and does not allow the bracket to fit flush against the wall, remove molding or mount bracket to the floor. For wall mount, locate the bracket by placing the back edge of the template against the rear wall and the side edge of template on the mark made referencing the side of the range. Place bracket on top of template and mark location of the screw holes in wall. If rear of range is further than 1 1/4-inches from the wall when installed, attach bracket to the floor. See Figure 14. For floor mount, locate the bracket by placing back edge of the template where the rear of the range will be located. Mark the location of the screw holes, shown in template. 2 Drill Pilot Holes and Fasten bracket Drill a 1/8-inch pilot hole where screws are to be located. If bracket is to be mounted to the wall, drill pilot hole at an approximate 20 degree downward angle. If bracket is to be mounted to masonry or ceramic floors, drill a 5/32-inch pilot hole 1 3/4-inches deep. The screws provided may be used in wood or concrete material. Use a 5/16-inch nut-driver or flat head screwdriver to secure the bracket in place. FASTEN BRACKET (WALL OR FLOOR MOUNTING) leveling leg max 11/4" wall mount 15" 15" Figure 12A The edge of the template should be aligned with the left or right edge of the range. wall plate floor mount Figure 13 Anti-Tip bracket FASTEN BRACKET (FLOOR MOUNTING ONLY) leveling leg more than 11/4" floor mount Figure 14 wall Anti-Tip bracket 13 3/8" 13 3/8" Figure 12B 13 3/8" from the center of the wall opening to the edge of the backet.