Sharp NP-PH3501QL Installation Guide - NEC - Page 11
PC Control Codes, Function Code Data
![]() |
View all Sharp NP-PH3501QL manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 11 highlights
Sharp NEC Display Solutions of America, Inc. PH3501QL Installation Guide Desktop and Ceiling Mount Rev 1.0 PC Control Codes Function POWER ON POWER OFF INPUT SELECT HDBaseT INPUT SELECT HDMI INPUT SELECT DisplayPort INPUT SELECT SLOT PICTURE MUTE ON PICTURE MUTE OFF Code Data 02H 00H 00H 00H 00H 02H 02H 01H 00H 00H 00H 03H 02H 03H 00H 00H 02H 01H 20H 28H 02H 03H 00H 00H 02H 01H A1H A9H 02H 03H 00H 00H 02H 01H A6H AEH 02H 03H 00H 00H 02H 01H ABH B3H 02H 10H 00H 00H 00H 12H 02H 11H 00H 00H 00H 13H Cable Connection Communication Protocol: Baud Rate: 38400 bps (for cable lengths longer than 20', it is recommended changing to 9600 bps in setup menu) Data Length: 8 bits Parity: No Parity Stop Bit: One bit X on/off: None Communications: Full duplex PC Control Connector (D-Sub 9P) Note 1 : Pins 1, 4, 6, and 9 are used inside the projector. Note 2: For long cable runs it is recommended to set communication speed within the projector to 9600 bps. Note 3: Jumper "Request to Send" and "Clear to Send" together on both ends of the cable to simplify cable connection. www.sharpnecdisplays.us PH3501QL Page 11 of 11