Sharp PG-C45S PG-C45S Operation Manual - Page 96
Wired Remote Control Terminal Specifications
UPC - 074000358683
View all Sharp PG-C45S manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 96 highlights
Wired Remote Control Terminal Specifications Specifications of wired remote control input • ø3.5 mm minijack • External: +5 V (1 A) • Internal: GND Function and transmisson codes CONTROL ITEM SYSTEM CODE DATA CODE EXTERNAL CODE C1 C2 C3 C4 C5 C6 C7 C8 C9 C10 C11 C12 C13 C14 C15 CONTROL ITEM ON 1 0 1 1 00 1 1 0 10 1 0 1 0 AUTO SYNC OFF VOLUME + VOLUME - MUTE MENU 1 0 1 1 00 1 1 0 10 0 1 1 0 1 0 1 1 00 0 1 0 10 0 0 1 0 1 0 1 1 01 0 1 0 10 0 0 1 0 1 0 1 1 01 1 1 0 10 0 0 1 0 1 0 1 1 00 0 1 0 00 1 1 1 0 GAMMA KEYSTONE 1 0 1 1 01 1 0 1 00 0 1 1 0 PinP BLACK SCREEN 1 0 1 1 0 1 0 0 1 0 1 1 0 1 0 BACK ENTER 1 0 1 1 01 1 1 0 10 1 0 1 0 FORWARD RESIZE 1 0 1 1 00 1 1 1 10 1 0 1 0 BREAK TIMER UNDO 1 0 1 1 01 0 0 1 10 1 0 1 0 INPUT 1 FREEZE 1 0 1 1 01 0 1 1 00 0 1 1 0 INPUT 2 ENLARGE (+) 1 0 1 1 0 1 0 1 1 0 1 1 0 1 0 INPUT 3 ENLARGE (-) 1 0 1 1 0 1 0 1 1 0 1 0 1 1 0 INPUT 4 SYSTEM CODE DATA CODE EXTERNAL CODE C1 C2 C3 C4 C5 C6 C7 C8 C9 C10 C11 C12 C13 C14 C15 1 0 1 1 00 1 0 1 11 1 1 1 0 1 0 1 1 00 0 1 1 10 0 1 1 0 1 0 1 1 01 0 1 1 10 0 1 1 0 1 0 1 1 00 0 0 0 10 1 0 1 0 1 0 1 1 01 1 1 1 00 1 0 1 0 1 0 1 1 00 0 0 0 00 1 0 1 0 1 0 1 1 01 1 1 1 11 1 1 1 0 1 0 1 1 00 1 1 1 01 0 1 1 0 1 0 1 1 01 1 1 1 01 0 1 1 0 1 0 1 1 00 0 1 0 11 0 1 1 0 1 0 1 1 01 0 1 0 11 0 0 1 0 1 0 1 1 00 1 1 0 11 0 0 1 0 1 0 1 1 00 1 0 0 11 0 0 1 0 1 0 1 1 01 1 0 0 11 0 0 1 0 Wired remote control function code LSB MSB C1 System Code C5 C6 1 0 1 1 0 * * Data Code * * * * C13 C14 C15 * * 1 0 • System codes C1 to C5 are fixed at "10110". • Codes C14 and C15 are reverse confirmation bits, with "10" indicating "Front" and "01" indicating "Rear". Sharp remote control signal format Transmission format: 15-bit format D D D D D D D D D D D D D 67.5 ms 67.5 ms Wave form of output signal: Output using Pulse Position Modulation t T1 T0 "1" "0" "0" "0" 26.4 µs "0" "1" "0" t D • t = 264 µs • T0 = 1.05 ms • T1 = 2.10 ms • Pulse carrier frequency = 455/12 kHz • Duty ratio = 1:1 Transmission control code 15 bit C1 C2 C3 C4 C5 C6 C7 C8 C9 C10 C11 C12 C13 C14 C15 System Address Function Key Data Bit Data Expansion Mask Data Deter- mination Example of Reverse D to D D C1 C2 C3 C4 C5 C6 C7 C8 C9 C10 C11 C12 C13 C14 C15 1 0 1 1 0 1 0 0 0 0 0 0 0 1 0 D C1 C2 C3 C4 C5 C6 C7 C8 C9 C10 C11 C12 C13 C14 C15 1 0 1 1 0 0 1 1 1 1 1 1 1 0 1 D to D Common Data Bit Reverse in D -92