Smeg C24GGXU Safety Guide - Page 3
Conversion Kit - head
View all Smeg C24GGXU manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 3 highlights
Conversion Kit Check that the main gas supply line to the range is shut off and that the power supply cord is disconnected. 1) Remove access cap "A" by using a screwdriver or a coin, turning the access cap counterclockwise. The gas pressure regulator has two settings which are indicated on two sides of the cap. Turn the cap and reinstall it in the regulator with "LP" visible from the outside of the regulator. Incoming line pressure upstream from the regulator must be 1" (2.5 cm) W.C.P. higher than the manifold pressure in order to check the regulator. Incoming line pressure to the regulator should be as follows for operation and checking 2) the regulator setting: - NATURAL GAS: Set pressure to 4" W.C.P. Incoming line pressure of 3 1/2" - 10 1/2" W.C.P maximum; - LP GAS: Set pressure to 11" W.C.P. Incoming line pressure 8"- 13" W.C.P. maximum. The range must be isolated from the gas supply piping system by turning off the respective manual shutoff valve during any pressure testing of the gas supply piping system at test pressures equal to or greater than 1/2 psig (3.5 kPa). Replacing the rangetop's burners nozzles (This operation does not require primary air regulation). 1 Remove the grates and all the burner caps and heads; 2 Unscrew the burner nozzles with a 7 mm socket wrench; 3 Replace the nozzles according to the type of gas to be used and the description in paragraph 3.2 "Burner and nozzle characteristics table". 4 Put the burners back in their correct position. 3) 5