Sony AITE200-UL Operating Instructions - Page 32
AITe90V-UL
View all Sony AITE200-UL manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 32 highlights
AITe90V-UL ■ Performance Storage Capacity Data Transfer Rate (TAPE) Burst Data Transfer Rate Bit Error Rate Load Time Unload Time Rewind Time 35 GB uncompressed (with 230 m AIT-1 data cartridge) 91 GB compressed (with 230 m AIT-1 data cartridge*1) 4 MB/s uncompressed 480 Mbps maximum (USB) 400 Mbps maximum (i.LINK) less than 10-17 average of 14 seconds*2 average of 20 seconds*2 average of 105 seconds*2 (with 230 m AIT-1 data cartridge) ■ Operating Environment Operating Non-operating Temperature: 10 °C to 35 °C (∆T
32
Appendix
AITe90V-UL
■
Performance
Storage Capacity
35 GB uncompressed (with 230 m AIT-1 data cartridge)
91 GB compressed (with 230 m AIT-1 data cartridge
*1
)
Data Transfer Rate (TAPE)
4 MB/s uncompressed
Burst Data Transfer Rate
480 Mbps maximum (USB)
400 Mbps maximum (i.LINK)
Bit Error Rate
less than 10
-17
Load Time
average of 14 seconds
*2
Unload Time
average of 20 seconds
*2
Rewind Time
average of 105 seconds
*2
(with 230 m AIT-1 data cartridge)
■
Operating Environment
Operating
Temperature:
10 °C to 35 °C (
∆
T<10 °C/h)
(50 °F to 95 °F (
∆
T<18 °F/h))
Humidity:
30 to 80% (non-condensing)
Maximum wet bulb temperature: 26 °C (78.8 °F)
Non-operating
Temperature:
–40 °C to 70 °C (
∆
T<20 °C/h)
(–40 °F to 158 °F (
∆
T<36 °F/h))
Humidity:
10 to 90% (
∆
RH<30%/h)
Maximum wet bulb temperature: 45 °C (113 °F)
■
Power Supply & Miscellaneous
Rated Power Supply
100 V to 240 V AC, 50/60 Hz, 1.2 A
Case Dimensions
198
×
64.5
×
246 mm (W
×
H
×
D) (excluding projections)
Mass
2.4 kg
Specifications may be subject to change, in the interest of technological
improvement, without notice or obligation.
*1
Assuming a 2.6:1 hardware compression ratio.
The actual degree of data compression during recording depends on the system environment
and type of data.
*2
No retries.