Sony BVME250 User Manual - Page 52

Color Profile data, S-LOG Standard - bvm e250 monitor

Page 52 highlights

Chapter 3 Menu Color Profile Menu Color Space Gamma Marker Preset Function and operation ([ ]: factory setting) Color Profile data BVM SMPTE-C: Displays with the color space and gamma of BVM SMPTE-C phosphor CRT. BVM EBU: Displays with the color space and gamma of BVM EBU phosphor CRT. ITU-R BT.709: Displays with the color space of three primary color chromaticity points provided by ITU-R BT.709 and gamma 2.4. D-Cine1): Displays with the color space of three primary color chromaticity points provided by SMPTE RP 431-2. E250 Native: Displays with the color space of the BVM-E250 individual three primary color chromaticity points. This is the widest color space setting of the signal reproduced by the BVM-E250. S-GAMUT/S-LOG: Displays with the color space of the transmission gamma S-LOG and the wide color space mode S-GAMUT, which is available for the output signal of F23 or F35 Digital Cinematography Camera. User CHXX: Select when the color space and gamma are to be set individually depending on the currently selected channel. 1) Three primary color chromaticity points provided by SMPTE RP 431-2 are not covered in full. Select the color space when User CHXX is selected in the Color Profile menu. SMPTE-C: Color space of three primary color chromaticity points provided by the SMPTE-C standard EBU: Color space of three primary color chromaticity points provided by the EBU standard ITU-R BT.709: Color space of three primary color chromaticity points provided by the ITU-R BT.709 standard D-Cine2): Color space of three primary color chromaticity points provided by SMPTE RP 431-2 E250 Native: Color space of the BVM-E250 individual three primary color chromaticity points 2) Three primary color chromaticity points provided by SMPTE RP 431-2 are not covered in full. Select the gamma when User CHXX is selected in the Color Profile menu. CRT BVM: Gamma curve of the BVM-D or BVM-A series 2.2: Gamma curve 2.2 2.4: Monitor gamma provided by "Reference Electro-Optical Transfer Function (EOTF) for flat displays used in HDTV studio production" of ITU-R standard 2.6: Gamma curve 2.6 S-LOG Standard: Log gamma available with the F23 or F35 Digital Cinematography Camera Select to run 100% output level of the camera with the 100% level of the monitor for confirmation. S-LOG Full: Log gamma available with the F23 or F35 Digital Cinematography Camera Select to fit the full dynamic range of the camera in the 100% level of the monitor for confirmation. Notes • The Gamma setting is fixed at 2.6 when an XYZ format signal is input. • The factory preset black luminance of the CRT BVM setting in the Gamma menu is the same as the factory preset value for a BVM-D or BVM-A series monitor. • Adjust the brightness (black level) according to the ambient light and the black level of the image to be reproduced. Adjust the contrast (white level) according to the ambient light. Sets the marker preset data. You can select from Marker1 to Marker5. [Marker1] For setting the marker, see the Marker Setting menu (page 56) of the Function Setting menu. 52 Channel Configuration Menu

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66
  • 67
  • 68
  • 69
  • 70
  • 71
  • 72
  • 73
  • 74
  • 75
  • 76
  • 77
  • 78
  • 79
  • 80
  • 81
  • 82
  • 83
  • 84
  • 85
  • 86
  • 87
  • 88
  • 89
  • 90
  • 91
  • 92
  • 93
  • 94
  • 95
  • 96
  • 97
  • 98
  • 99
  • 100
  • 101
  • 102
  • 103
  • 104
  • 105
  • 106
  • 107
  • 108
  • 109
  • 110
  • 111
  • 112
  • 113
  • 114
  • 115
  • 116
  • 117
  • 118
  • 119
  • 120
  • 121
  • 122
  • 123
  • 124
  • 125
  • 126
  • 127
  • 128
  • 129
  • 130
  • 131
  • 132
  • 133
  • 134
  • 135
  • 136

52
Channel Configuration Menu
Chapter 3
Menu
Color Profile
Color Profile data
BVM SMPTE-C:
Displays with the color space and gamma of BVM SMPTE-C phosphor
CRT.
BVM EBU:
Displays with the color space and gamma of BVM EBU phosphor CRT.
ITU-R BT.709:
Displays with the color space of three primary color chromaticity points
provided by ITU-R BT.709 and gamma 2.4.
D-Cine
1)
:
Displays with the color space of three primary color chromaticity points
provided by SMPTE RP 431-2.
E250 Native:
Displays with the color space of the BVM-E250 individual three primary
color chromaticity points.
This is the widest color space setting of the signal reproduced
by the BVM-E250.
S-GAMUT/S-LOG:
Displays with the color space of the transmission gamma S-LOG and
the wide color space mode S-GAMUT, which is available for the output signal of F23 or
F35 Digital Cinematography Camera.
User CHXX:
Select when the color space and gamma are to be set individually
depending on the currently selected channel.
1) Three primary color chromaticity points provided by SMPTE RP 431-2 are not covered in full.
Color Space
Select the color space when User CHXX is selected in the Color Profile menu.
SMPTE-C:
Color space of three primary color chromaticity points provided by the
SMPTE-C standard
EBU:
Color space of three primary color chromaticity points provided by the EBU
standard
ITU-R BT.709:
Color space of three primary color chromaticity points provided by the
ITU-R BT.709 standard
D-Cine
2)
:
Color space of three primary color chromaticity points provided by SMPTE RP
431-2
E250 Native:
Color space of the BVM-E250 individual three primary color chromaticity
points
2) Three primary color chromaticity points provided by SMPTE RP 431-2 are not covered in full.
Gamma
Select the gamma when User CHXX is selected in the Color Profile menu.
CRT BVM:
Gamma curve of the BVM-D or BVM-A series
2.2:
Gamma curve 2.2
2.4:
Monitor gamma provided by “Reference Electro-Optical Transfer Function (EOTF)
for flat displays used in HDTV studio production” of ITU-R standard
2.6:
Gamma curve 2.6
S-LOG Standard:
Log gamma available with the F23 or F35 Digital Cinematography
Camera
Select to run 100% output level of the camera with the 100% level of the monitor for
confirmation.
S-LOG Full:
Log gamma available with the F23 or F35 Digital Cinematography Camera
Select to fit the full dynamic range of the camera in the 100% level of the monitor for
confirmation.
Notes
The Gamma setting is fixed at 2.6 when an XYZ format signal is input.
The factory preset black luminance of the CRT BVM setting in the Gamma menu is the
same as the factory preset value for a BVM-D or BVM-A series monitor.
Adjust the brightness (black level) according to the ambient light and the black level of the
image to be reproduced. Adjust the contrast (white level) according to the ambient light.
Marker Preset
Sets the marker preset data.
You can select from
Marker1
to
Marker5
.
[Marker1]
For setting the marker, see the Marker Setting menu (page 56) of the Function Setting menu.
Menu
Function and operation ([