Sony CCD-TR517WR Primary User Manual - Page 50
Troubleshooting, Others
View all Sony CCD-TR517WR manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 50 highlights
Troubleshooting Symptom Cause and/or Corrective Actions The cassette cannot be removed from the holder. • The power source is disconnected. c Connect it firmly. (p. 8, 13) • The battery is dead. c Use a charged battery pack. (p. 8, 9) The % and Z indicators flash and no functions except for cassette ejection work. • Moisture condensation has occurred. c Remove the cassette and leave your camcorder for at least 1 hour to acclimatize. (p. 54) Others Symptom Cause and/or Corrective Actions The date or time indicator does not • Reset the date and time. (p. 43) appear, and the bars "--:--:--" appear. The melody or beep sounds for 5 seconds. • Moisture condensation has occurred. c Remove the cassette and leave your camcorder for at least 1 hour to acclimatize. (p. 54) • Some troubles has occurred in your camcorder. c Remove the cassette and insert it again, then operate your camcorder. While charging the battery pack, no indicator appears or the indicator flashes in the display window. • The AC power adaptor is disconnected. c Connect it firmly. (p. 9) • Something is wrong with the battery pack. c Contact your Sony dealer or local authorized Sony service facility. 50