Page 23 highlights
Mode "03" Alarm On AE moves. AE moves outside of the hysteresis. High level signal output * * Repeat this loop until Alarm off. AE does not move for a period of time. Low level signal output Update the AE level data Basic Functions AE level into memory Hysteresis is set to the factory preset. AE does not move for a period of time. 23
23
Basic Functions
Mode “03”
Alarm On
AE level into memory
AE moves.
Hysteresis is set to the factory
preset.
AE moves outside of
the hysteresis.
High level signal output
*
Repeat this loop until Alarm off.
*
AE does not move for
a period of time.
AE does not move for
a period of time.
Low level signal output
Update the AE level data