Sony FWD-42PX2 Protocol Manual - Page 11
Code Table1-a, IP Address
View all Sony FWD-42PX2 manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 11 highlights
Code Table(1-a) [a]Function [b]Range/Switch Code Command Control Enquiry Standby Power On 0x35 PAP Input Detect*2 (Left/Main) 0x0A INPUT2 RGB No 0x0B INPUT2 COMPONENT Yes Disable Enable 0x0C OPTION1 VIDEO 0x0D OPTION1 S VIDEO 0x0E OPTION1 RGB 0x0F OPTION1 COMPONENT 0x10 OPTION2 VIDEO 0x11 OPTION2 S VIDEO 0x12 OPTION2 RGB 0x13 OPTION2 COMPONENT 0x20 INPUT1 DVI 0x36 PAP Input Detect*2 (Right/Sub) 0x0A INPUT2 RGB No 0x0B INPUT2 COMPONENT Yes Disable Enable 0x0C OPTION1 VIDEO 0x0D OPTION1 S VIDEO 0x0E OPTION1 RGB 0x0F OPTION1 COMPONENT 0x10 OPTION2 VIDEO 0x11 OPTION2 S VIDEO 0x12 OPTION2 RGB 0x13 OPTION2 COMPONENT 0x20 INPUT1 DVI *1: Transmit the next command 10 seconds after Power On and Power Off commands are transmitted. If not, correct data may not be able to be acquired. *2: The command of Option 2 slot is assigned to Option 1 slot because the BKM-FW32 is installed in Option 2 slot. *3: The Picture Position arrangement is as shown below. 12 34 IP Address Syntax Control Header 0x8C Category 0x00 Function 0x42 Data1 0x05 Data2 Data3 Address Address 1 00x00-0xFF 0x00-0xFF Data4 Address 2 0x00-0xFF Data5 Address 3 0x00-0xFF Check Sum 0xXX Answer Header Answer Check Sum Control 0x70 0x00 0x70 Completed 0x70 0x03 0x73 Command Canceled IP Address ex) 192.128.14.1 → 192 (0xC0) Address 0 128 (0x80) Address 1 14 (0x0E) Address 2 1 (0x01) Address 3 * IP Address command can be carried out even in the standby state. FWD-42PX2 7