Administrating the Camera Date & time format Select the format of date and time to be displayed on the main viewer from the list box. You can select from among yyyy-mm-dd hh:mm:ss (year-month-day hour:minute:second), mm-dd-yyyy hh:mm:ss (month-day-year hour:minute:second), and dd-mm-yyyy hh:mm:ss (day-month-year hour:minute:second). Adjust Select to set the day and time. Keep current setting: Select when you do not need to set the date and time. Synchronize with PC: Select when synchronizing the camera's date and time with those of the computer. Manual setting: Select when you want to set the camera's date and time manually. Select the lower 2-digits of year, month, date, hour, minutes and seconds from each drop-down list. Synchronize with NTP: Select when synchronizing the camera's date and time with those of the time sever called NTP server (Network Time Protocol). Set the NTP server name and the Interval time. NTP server name Type the host name or IP address of the NTP server, up to 64 characters. Interval time Select the interval at which you want to adjust the camera's time referring to the NTP server' time, between 1 and 24 hours. The set interval is a guide, and does not indicate the exact time. Note The setting time may not accord with the exact time according to the network environment. Time zone Set the time difference from Greenwich Mean Time in the area where the camera is installed. Select the time zone where the camera is installed from the list box. Automatically adjust clock for daylight saving time changes When you select it, the clock is automatically adjusted according to the daylight saving time of the selected time zone. Note If the time zone selected on the Time zone menu is different from that set on the computer, the time is adjusted using the time zone difference and set on the camera. OK/Cancel See "Buttons common to every setting menu" on page 34. Initialize Tab Reboot Reboots the camera. Click Reboot, and "The SNC-P5 will be rebooted. Are you sure?" appears. Click OK to reboot the camera. It takes about two minutes to start again. Factory default Resets the camera to the factory settings. Click Factory default, and "Set up data will be initialized. Are you sure?" appears. When you click OK, the network indicator on the camera starts to blink. After adjustments of the default settings have finished, the camera reboots automatically. Do not turn off the camera until the camera reboots. Tip You can also reset the camera to the factory setting by turning on the power while pressing the reset switch of the camera. For details, refer to the supplied Installation Manual. Backup setting data Saves the setting data of the camera in a file. Click Save, and follow the instructions on the Web browser to specify the folder and save the setting data of the camera. The file name preset at the factory is "sncp5.cfg." Restore setting Loads the stored setting data of the camera. 37 Configuring the System - System setting menu

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66
  • 67
  • 68
  • 69
  • 70
  • 71
  • 72
  • 73
  • 74
  • 75
  • 76
  • 77
  • 78
  • 79
  • 80
  • 81
  • 82
  • 83
  • 84
  • 85
  • 86
  • 87
  • 88
  • 89
  • 90

Administrating the Camera
Configuring the System — System setting menu
37
Date & time format
Select the format of date and time to be displayed on the
main viewer from the list box.
You can select from among
yyyy-mm-dd hh:mm:ss
(year-month-day hour:minute:second),
mm-dd-yyyy
hh:mm:ss
(month-day-year hour:minute:second), and
dd-mm-yyyy hh:mm:ss
(day-month-year
hour:minute:second).
Adjust
Select to set the day and time.
Keep current setting:
Select when you do not need to
set the date and time.
Synchronize with PC:
Select when synchronizing the
camera’s date and time with those of the computer.
Manual setting:
Select when you want to set the
camera’s date and time manually.
Select the lower 2-digits of year, month, date, hour,
minutes and seconds from each drop-down list.
Synchronize with NTP:
Select when synchronizing the
camera’s date and time with those of the time sever
called NTP server (Network Time Protocol). Set the
NTP server name
and the
Interval
time.
NTP server name
Type the host name or IP address of the NTP server, up
to 64 characters.
Interval time
Select the interval at which you want to adjust the
camera’s time referring to the NTP server’ time,
between 1 and 24 hours.
The set interval is a guide, and
does not indicate the exact time.
Note
The setting time may not accord with the exact time
according to the network environment.
Time zone
Set the time difference from Greenwich Mean Time in
the area where the camera is installed.
Select the time zone where the camera is installed from
the list box.
Automatically adjust clock for daylight saving
time changes
When you select it, the clock is automatically adjusted
according to the daylight saving time of the selected
time zone.
Note
If the time zone selected on the
Time zone
menu is
different from that set on the computer, the time is
adjusted using the time zone difference and set on the
camera.
OK/Cancel
See “Buttons common to every setting menu” on page
34.
Initialize Tab
Reboot
Reboots the camera.
Click
Reboot
, and “The SNC-P5 will be rebooted.
Are
you sure?” appears.
Click
OK
to reboot the camera.
It
takes about two minutes to start again.
Factory default
Resets the camera to the factory settings.
Click
Factory default
, and “Set up data will be
initialized.
Are you sure?” appears.
When you click
OK
, the network indicator on the camera starts to blink.
After adjustments of the default settings have finished,
the camera reboots automatically. Do not turn off the
camera until the camera reboots.
Tip
You can also reset the camera to the factory setting by
turning on the power while pressing the reset switch of
the camera. For details, refer to the supplied Installation
Manual.
Backup setting data
Saves the setting data of the camera in a file.
Click
Save
, and follow the instructions on the Web
browser to specify the folder and save the setting data of
the camera. The file name preset at the factory is “snc-
p5.cfg.”
Restore setting
Loads the stored setting data of the camera.