Sony VPL CX5 Operating Instructions - Page 41

Warning Messages - replacement lamp for vplcs5

Page 41 highlights

Maintenance Remote Commander Symptom Cause and Remedy The Remote Commander • The Remote Commander batteries are dead. does not work. c Replace with a new battery (see page 15). Others Symptom Cause and Remedy The LAMP/COVER indicator flashes. • The lamp cover or the air filter cover is detached. c Attach the cover securely (see pages 36 and 37). The LAMP/COVER indicator lights up. • The lamp has reached the end of its life. c Replace the lamp (see page 36). • The lamp becomes a high temperature. c Wait for 90 seconds to cool down the lamp and turn on the power again (see page 26). The TEMP/FAN indicator • The fan is broken. flashes. c Consult with qualified Sony personnel. The TEMP/FAN indicator • The internal temperature is unusually high. lights up. c Check to see if nothing is blocking the ventilation holes. Both the LAMP/COVER • The electrical system breaks down. and TEMP/FAN indicators c Consult with qualified Sony personnel. light up. Warning Messages Use the list below to check the meaning of the messages displayed on the screen. Message Meaning and Remedy High temp.! Lamp off in 1 min. • Internal temperature is too high. c Turn off the power. c Check to see if nothing is blocking the ventilation holes. Frequency is out of range! • This input signal cannot be projected as the frequency is out of the acceptable range of the projector. c Input a signal that is within the range of the frequency. • The resolution setting of the output signal of a computer is too high. c Set the setting of output to XGA (VPL-CX5) or SVGA (VPLCS5) (see page 17). Please check INPUT-A setting. • You have input RGB signal from the computer when "Input-A Signal Sel." in the SET SETTING menu is set to "Component." c Set "Input-A Signal Sel." correctly (see page 33). Please replace the LAMP. • It is time to replace the lamp. c Replace the lamp. Troubleshooting 41 GB

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66
  • 67
  • 68
  • 69
  • 70
  • 71
  • 72
  • 73
  • 74
  • 75
  • 76
  • 77
  • 78
  • 79
  • 80
  • 81
  • 82
  • 83
  • 84
  • 85
  • 86
  • 87
  • 88
  • 89
  • 90
  • 91
  • 92
  • 93
  • 94
  • 95
  • 96
  • 97
  • 98
  • 99
  • 100
  • 101
  • 102
  • 103
  • 104
  • 105
  • 106
  • 107
  • 108
  • 109
  • 110
  • 111
  • 112
  • 113
  • 114
  • 115
  • 116
  • 117
  • 118
  • 119
  • 120
  • 121
  • 122
  • 123
  • 124
  • 125
  • 126
  • 127
  • 128
  • 129
  • 130
  • 131
  • 132
  • 133
  • 134
  • 135
  • 136
  • 137
  • 138
  • 139
  • 140
  • 141
  • 142
  • 143
  • 144
  • 145
  • 146
  • 147
  • 148

41
GB
Troubleshooting
Maintenance
Remote Commander
Others
Warning Messages
Use the list below to check the meaning of the messages displayed on the screen.
Symptom
Cause and Remedy
The Remote Commander
does not work.
• The Remote Commander batteries are dead.
c
Replace with a new battery (see page 15).
Symptom
Cause and Remedy
The LAMP/COVER
indicator flashes.
• The lamp cover or the air filter cover is detached.
c
Attach the cover securely (see pages 36 and 37).
The LAMP/COVER
indicator lights up.
• The lamp has reached the end of its life.
c
Replace the lamp (see page 36).
• The lamp becomes a high temperature.
c
Wait for 90 seconds to cool down the lamp and turn on the
power again (see page 26).
The TEMP/FAN indicator
flashes.
• The fan is broken.
c
Consult with qualified Sony personnel.
The TEMP/FAN indicator
lights up.
• The internal temperature is unusually high.
c
Check to see if nothing is blocking the ventilation holes.
Both the LAMP/COVER
and TEMP/FAN
indicators
light up.
• The electrical system breaks down.
c
Consult with qualified Sony personnel.
Message
Meaning and Remedy
High temp.!
Lamp off in 1 min.
• Internal temperature is too high.
c
Turn off the power.
c
Check to see if nothing is blocking the ventilation holes.
Frequency is out of range!
• This input signal cannot be projected as the frequency is out of the
acceptable range of the projector.
c
Input a signal that is within the range of the frequency.
• The resolution setting of the output signal of a computer is too
high.
c
Set the setting of output to XGA (VPL-CX5) or SVGA (VPL-
CS5) (see page 17).
Please check INPUT-A
setting.
• You have input RGB signal from the computer when “Input-A
Signal Sel.” in the SET SETTING menu is set to “Component.”
c
Set “Input-A Signal Sel.” correctly (see page 33).
Please replace the LAMP.
• It is time to replace the lamp.
c
Replace the lamp.