S U B - Z E R O B U I LT- I N U S E & C A R E CLEAN ING CO M BI N ATI ON U N I TS For Models 611, 611G, 650, 650G, 661, 642, 632, 685 and 695, it is possible to turn off one section of your combination unit for an extended period without disrupting the other. First, turn the unit off, then push and hold the WARMER key pad of the section you want to disable. Then, turn the unit back on by depressing the UNIT ON/OFF key pad. The disabled section will be indicated with "--" in the Control Center display panel. Repeat the process to turn the section back on. See Electronic Control System, page 12. CLEANING THE ICE CHUTE For Models 685 and 695, ice crescents may occasionally become lodged in the ice chute. The ice chute is a clear plastic housing that directs ice from the freezer ice bucket to the glasswell ice dispenser in the door. To remove these obstructions, first remove the adjacent shelves, then remove the screw in the lower left corner of the side panel. Hold the bottom of the side panel and push rearward, then pull out. Once the panel is removed, the ice chute will be visible. Refer to the illustration below. To remove the side cover of the ice chute, press the two side locking tabs, then pull up and out. To reinstall, make sure the bottom section of the ice chute is installed first. Then fit the outside front cover lip inside the stationary portion. Finally, push the two assemblies together and close the self-locking tabs. Locking Tab Ice chute - Models 685 and 695 23

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40

23
CLEANING COMBINATION UNITS
For Models 611, 611G, 650, 650G, 661, 642,
632, 685 and 695, it is possible to turn off one
section of your combination unit for an
extended period without disrupting the other.
First, turn the unit off, then push and hold the
WARMER
key pad of the section you want to
disable. Then, turn the unit back on by
depressing the
UNIT ON/OFF
key pad. The
disabled section will be indicated with "--" in
the Control Center display panel. Repeat the
process to turn the section back on. See
Electronic Control System, page 12.
CLEANING THE ICE CHUTE
For Models 685 and 695, ice crescents may
occasionally become lodged in the ice chute.
The ice chute is a clear plastic housing that
directs ice from the freezer ice bucket to the
glasswell ice dispenser in the door.
To remove these obstructions, first remove the
adjacent shelves, then remove the screw in the
lower left corner of the side panel. Hold the
bottom of the side panel and push rearward,
then pull out. Once the panel is removed, the
ice chute will be visible. Refer to the illustra-
tion below.
To remove the side cover of the ice chute,
press the two side locking tabs, then pull up
and out. To reinstall, make sure the bottom
section of the ice chute is installed first. Then
fit the outside front cover lip inside the station-
ary portion. Finally, push the two assemblies
together and close the self-locking tabs.
Locking
Tab
Ice chute – Models 685 and 695
SUB-ZERO
BUILT-IN
USE & CARE