Sub-Zero BI-48SID Sub-Zero Design Guide - Page 56
Integrated Refrigeration, Electrical Requirements
View all Sub-Zero BI-48SID manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 56 highlights
Integrated Refrigeration 56 Electrical Requirements The electrical supply should be located within the shaded area shown in the illustrations. Follow the National Electrical Code and local codes and ordinances when installing the receptacle. A separate circuit, servicing only this appliance, is required. A ground fault circuit interrupter (GFCI) is not recommended and may cause interruption of operation. IMPORTANT NOTE: It is critical that the electrical outlet be located within the shaded area shown so it does not interfere with installation of the anti-tip bracket. It must be flush with the back wall and positioned with the grounding prong to the right of the thinner blades. Electrical Requirements Power Supply Circuit Breaker Receptacle 115 V AC, 60 Hz 15 amp 3-prong grounding-type LEFT SIDE OF OPENING LEFT SIDE OF OPENING 21/2" (64) 13" (330) 41/2" (114) 1/4" FLOOR (6) FRONT VIEW 21/2" (64) 171/2" (445) 1/4" FLOOR (6) FRONT VIEW 41/2" (114) 27" (686) models. 36" (914) models.