Sub-Zero UC-24RO Undercounter Installation Guide - Page 6

Site Preparation, Plumbing Requirements, Electrical Requirements

Page 6 highlights

Site Preparation 6 Electrical Requirements The electrical supply should be located within the shaded area shown in the illustration below. Follow the National Electrical Code and local codes and ordinances when installing the receptacle. A separate circuit, servicing only this appliance is required. IMPORTANT NOTE: The electrical outlet must be placed so the grounding prong is to the right of the thinner blades. The outlet must be flush with the back wall. Model UC-24RO is designed and safe for use in outdoor applications. When installed outdoors, a ground fault circuit interrupter (GFCI) is required to reduce the risk of electrical shock. A GFCI is not recommended for use with other undercounter models and may cause interruption of operation. Do not use an extension cord or two-prong adapter. Electrical ground is required on this appliance. Electrical Requirements Power Supply Circuit Breaker Receptacle 115 V AC, 60 Hz 15 amp 3-prong grounding-type Plumbing Requirements MODEL UC-24CI For model UC-24CI, the water supply line for the ice maker should be located within the shaded area shown in the illustration below. Connect the water line from the ice maker water valve to the house water supply line. Use an easily accessible shut-off valve between the water supply and the unit. Do not use self-piercing valves. A saddle valve kit is available from your authorized Sub-Zero dealer. A line filter is required when water conditions have a high sediment content. The ice maker operates on water pressure of 20 psi (1.4 bar) to 100 psi (6.9 bar). A reverse osmosis system can be used, provided there is a consistent water pressure of 20 psi (1.4 bar) to 100 psi (6.9 bar) supplied to the water valve at all times. A copper line is not recommended for this application. IMPORTANT NOTE: In some cases a reverse osmosis water filter system may not be able to maintain the minimum water pressure consistently. Plumbing Requirements Water Supply Line 1/4" OD copper, braided stainless steel or PEX tubing Water Pressure 20-100 psi (1.4-6.9 bar) Excess Water Line for Connection 26" (660) min LEFT SIDE OF OPENING 2" (51) 151/2" (394) 3" (76) FRONT VIEW Location of electrical supply. SHADED AREA EXTENDS 1/2" (13) FROM BACK WALL 2" (51) 151/2" (394) 3" (76) FRONT VIEW Location of water supply.

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16

Site Preparation
6
FRONT VIEW
15
1
/
2
"
(394)
3"
(76)
2"
(51)
LEFT SIDE
OF OPENING
Location of electrical supply.
Plumbing Requirements
MODEL UC-24CI
For model UC-24CI, the water supply line for the ice
maker should be located within the shaded area shown in
the illustration below. Connect the water line from the ice
maker water valve to the house water supply line. Use an
easily accessible shut-off valve between the water supply
and the unit. Do not use self-piercing valves. A saddle
valve kit is available from your authorized Sub-Zero
dealer.
A line filter is required when water conditions have a high
sediment content. The ice maker operates on water
pressure of 20 psi
(1.4 bar)
to 100 psi
(6.9 bar)
.
A reverse osmosis system can be used, provided there is
a consistent water pressure of 20 psi
(1.4 bar)
to 100 psi
(6.9 bar)
supplied to the water valve at all times. A copper
line is not recommended for this application.
IMPORTANT NOTE:
In some cases a reverse osmosis
water filter system may not be able to maintain the
minimum water pressure consistently.
FRONT VIEW
SHADED AREA
EXTENDS
1
/
2
"
(13)
FROM BACK WALL
15
1
/
2
"
(394)
3"
(76)
2"
(51)
Location of water supply.
Electrical Requirements
The electrical supply should be located within the shaded
area shown in the illustration below. Follow the National
Electrical Code and local codes and ordinances when
installing the receptacle. A separate circuit, servicing only
this appliance is required.
IMPORTANT NOTE:
The electrical outlet must be placed
so the grounding prong is to the right of the thinner
blades. The outlet must be flush with the back wall.
Model UC-24RO is designed and safe for use in outdoor
applications. When installed outdoors, a ground fault
circuit interrupter (GFCI) is required to reduce the risk of
electrical shock. A GFCI is not recommended for use with
other undercounter models and may cause interruption of
operation.
Electrical Requirements
Power Supply
115 V AC, 60 Hz
Circuit Breaker
15 amp
Receptacle
3-prong grounding-type
Do not use an extension cord or two-prong adapter.
Electrical ground is required on this appliance.
Plumbing Requirements
Water Supply Line
1
/
4
" OD copper, braided stainless steel
or PEX tubing
Water Pressure
20–100 psi
(1.4–6.9 bar)
Excess Water Line for Connection
26"
(660)
min