DA-6400 RS-422 command implementation revision : 1 page 3 of 4 Table 3 : 4x,6x,7x command : part 1 command to the DA-6400 command name cmd1 cmd2 data current time sense timer1 reset status sense edit preset edit preset sense tape/auto select 40 08 4y 30 41 32 request to the DA-6400 cmd1 cmd2 data 61 0C 01 03 04 10/30 11/33 61 20 61 30 return from the DA-6400 cmd1 cmd2 data Remarks 74 04 Time data indicates the LTC time. 74 06 Time data indicates the LTC time. 74 00 Time data indicates the lap time. 74 05/07 LTC user bits 78 04/06 LTC time & user bits 70 0D Request time data missing No action is taken, though the DA-6400 returns an ACK. 7x 20 x = 0 ~ F y = 1 ~ F 7x 30 x = 0 ~ F No action is taken, though the DA-6400 returns an ACK. servo ref select 4x 33 No action is taken, though the DA-6400 returns an ACK. head select color frame select timer mode select auto mode off autp mode on video reference disable off video reference disable on 4x 34 4x 35 4x 36 40 40 40 41 40 48 40 49 No action is taken, though the DA-6400 returns an ACK. No action is taken, though the DA-6400 returns an ACK. No action is taken, though the DA-6400 returns an ACK. No action is taken, though the DA-6400 returns an ACK. No action is taken, though the DA-6400 returns an ACK. No action is taken, though the DA-6400 returns an ACK. No action is taken, though the DA-6400 returns an ACK.

  • 1
  • 2
  • 3
  • 4

DA-6400 RS-422 command implementation
revision : 1
page 3 of 4
Table 3 : 4x,6x,7x command : part 1
command to the DA-6400
request to the DA-6400
return from the DA-6400
command name
cmd1
cmd2
data
cmd1 cmd2
data
cmd1 cmd2
data
Remarks
current time sense
61
0C
01
74
04
<time 4>
Time data indicates the LTC time.
03
74
06
<time 4>
Time data indicates the LTC time.
04
74
00
<time 4>
Time data indicates the lap time.
10/30
74
05/07
<UB>
LTC user bits
11/33
78
04/06
<time 4 & UB>
LTC time & user bits
70
0D
Request time data missing
timer1 reset
40
08
No action is taken, though the DA-6400 returns an ACK.
status sense
61
20
<data area>
7x
20
<status>
x = 0 ~ F
edit preset
4y
30
y = 1 ~ F
edit preset sense
61
30
<data area>
7x
30
<edit preset data>
x = 0 ~ F
tape/auto select
41
32
<t/a data>
No action is taken, though the DA-6400 returns an ACK.
servo ref select
4x
33
<data>
No action is taken, though the DA-6400 returns an ACK.
head select
4x
34
<data>
No action is taken, though the DA-6400 returns an ACK.
color frame select
4x
35
<data>
No action is taken, though the DA-6400 returns an ACK.
timer mode select
4x
36
<data>
No action is taken, though the DA-6400 returns an ACK.
auto mode off
40
40
No action is taken, though the DA-6400 returns an ACK.
autp mode on
40
41
No action is taken, though the DA-6400 returns an ACK.
video reference disable off
40
48
No action is taken, though the DA-6400 returns an ACK.
video reference disable on
40
49
No action is taken, though the DA-6400 returns an ACK.