TASCAM SS-R200 SS-CDR200 RS-232C documentation - Page 14

CLOCK DATA PRESET, Description, Remarks, Data 1, Data 2, Data 3, Data 4, Data 5, Data 6, Data 7,

Page 14 highlights

RS-232C Protocol Specifications Rev. 1.00 SS-CDR200/SS-R200 ・CLOCK DATA PRESET CLOCK DATA PRESET sets the date and time information for the controlled device. Only when this command is sent with request data ([FF]), the controlled device sends the CLOCK DATA RETURN command [A7]. Command 27 Data 10 bytes or 2 bytes Return Clock Data Preset Return [A7] Data 1 Description Tens digit of the year (A.D.). Remarks Data 2 Data 3 Data 4 Ones digit of the year (A.D.). Tens digit of the month. Ones digit of the month. [Example] 0802231234: February 23, 2008 / 12:34 Data 5 Data 6 Data 7 Data 8 Tens digit of the date Ones digit of the date Tens digit of the hour. Ones digit of the hour If data 1 and data 2 are both "F", the controlled device returns the current Clock Data setting. Data 9 Tens digit of the minute Data 10 Ones digit of the minute ・if the specified data does not exist, the controlled device sends ILLEGAL [F2]. ・SYNC REC LEVEL PRESET SYNC REC LEVEL PRESET sets the level of the sync recording of the controlled device. Only when this command is sent with request data ([FF]), the controlled device sends the SYNC REC LEVEL RETURN command [A8]. The sync rec mode can be turned on or off using the SYNC REC SELECT command [38]. Command 28 Data 2 bytes Return Sync Rec Level Return [A8] Data 1 Data 2 Description Remarks 0 0 -24dB Sync Rec level setting is -24 dB. 0 1 -30dB Sync Rec level setting is -30 dB. 0 2 -36dB Sync Rec level setting is -36 dB. 0 3 -42dB Sync Rec level setting is -42 dB. 0 4 -48dB Sync Rec level setting is -48 dB. 0 5 -54dB Sync Rec level setting is -54 dB. 0 6 -60dB Sync Rec level setting is -60 dB. 0 7 -66dB Sync Rec level setting is -66 dB. 0 8 -72dB Sync Rec level setting is -72 dB. F F Sense Requests the controlled device to return the current Sync Rec Level setting. ・if the specified data is out of rage, the controlled device sends ILLEGAL [F2]. - 14 -

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35

RS-232C Protocol Specifications Rev. 1.00
SS-CDR200/SS-R200
- 14 -
CLOCK DATA PRESET
CLOCK DATA PRESET sets the date and time information for the controlled device.
Only when this command is sent with request data ([FF]), the controlled device sends the CLOCK DATA
RETURN command [A7].
Command
27
Data
10 bytes or 2 bytes
Return
Clock Data Preset Return [A7]
Description
Remarks
Data 1
Tens digit of the year (A.D.).
Data 2
Ones digit of the year (A.D.).
Data 3
Tens digit of the month.
Data 4
Ones digit of the month.
Data 5
Tens digit of the date
Data 6
Ones digit of the date
Data 7
Tens digit of the hour.
Data 8
Ones digit of the hour
Data 9
Tens digit of the minute
Data 10
Ones digit of the minute
[Example]
0802231234: February 23, 2008 / 12:34
If data 1 and data 2 are both “F”, the
controlled device returns the current Clock
Data setting.
if the specified data does not exist, the controlled device sends ILLEGAL [F2].
SYNC REC
LEVEL PRESET
SYNC REC LEVEL PRESET sets the level of the sync recording of the controlled device.
Only when this command is sent with request data ([FF]), the controlled device sends the SYNC REC LEVEL
RETURN command [A8].
The sync rec mode can be turned on or off using the SYNC REC SELECT command [38].
Command
28
Data
2 bytes
Return
Sync Rec Level Return [A8]
Data 1
Data 2
Description
Remarks
0
0
-24dB
Sync Rec level setting is -24 dB.
0
1
-30dB
Sync Rec level setting is -30 dB.
0
2
-36dB
Sync Rec level setting is -36 dB.
0
3
-42dB
Sync Rec level setting is -42 dB.
0
4
-48dB
Sync Rec level setting is -48 dB.
0
5
-54dB
Sync Rec level setting is -54 dB.
0
6
-60dB
Sync Rec level setting is -60 dB.
0
7
-66dB
Sync Rec level setting is -66 dB.
0
8
-72dB
Sync Rec level setting is -72 dB.
F
F
Sense
Requests the controlled device to return the current Sync Rec
Level setting.
if the specified data is out of rage, the controlled device sends ILLEGAL [F2].