TEAC HD-P2 HD-P2 Software Updates v. 1.05 Release Notes - Page 9

Disk Status, Reset to Factory Defaults, Pull Up/Down Sample Rate Settings, HH:MM format.

Page 9 highlights

Disk Status The display and icon in the lower right of the LCD screen displays the time remaining available to record on the inserted media at the selected sample rate and bit depth in HH:MM format. Momentarily holding STOP will display the actual space remaining on the media Reset to Factory Defaults Under the Default Project Settings menu there is a selection to initialize all of the HDP2's settings to their factory defaults. Pull Up/Down Sample Rate Settings A pull up/down sample rate is always relative to the chosen time code rate. For example, when it is required to chase 30fps LTC but the project will eventually be pulled down to 29.97, a 30 Pull Up setting would be used providing an operating sample rate of the selected sample rate plus 0.1% while chasing 30fps LTC. Later, when chasing 29.97, the sample rate will be normal. The following 0.1% pull up/down rates are supported by the HD-P2: 23.976 Pull Down 24.00 Pull Up 24.975 Pull Down 25.00 Pull Up 29.97 Pull Down 30.00 Pull Up If 1% or 4% pull up/down rates are required, the HD-P2 must be locked to an external clock source providing that rate. Pre-Record The pre-record buffer is not active when the HD-P2 is set to chase timecode.

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9

Disk Status
The display and icon in the lower right of the LCD screen displays the time remaining
available to record on the inserted media at the selected sample rate and bit depth in
HH:MM format.
Momentarily holding STOP will display the actual space remaining on
the media
Reset to Factory Defaults
Under the
Default Project Settings
menu there is a selection to initialize all of the HD-
P2’s settings to their factory defaults.
Pull Up/Down Sample Rate Settings
A pull up/down sample rate is always relative to the chosen time code rate.
For example, when it is required to chase 30fps LTC but the project will eventually be
pulled down to 29.97, a 30 Pull Up setting would be used providing an operating sample
rate of the selected sample rate plus 0.1% while chasing 30fps LTC.
Later, when chasing
29.97, the sample rate will be normal.
The following 0.1% pull up/down rates are supported by the HD-P2:
23.976 Pull Down
24.00 Pull Up
24.975 Pull Down
25.00 Pull Up
29.97 Pull Down
30.00 Pull Up
If 1% or 4% pull up/down rates are required, the HD-P2 must be locked to an external
clock source providing that rate.
Pre-Record
The pre-record buffer is not active when the HD-P2 is set to chase timecode.