8 7 6 5 4 3 2 1 POWER Figure 3-2 TL-SG1008D Switch Rear Panel sketch 3.3 LED indicators The LED indicators include Power LED and Link/Act LEDs (See Figure 3-1). The LED indicators are used for monitoring and troubleshooting of the Switch. The following section shows the LED indicators for the Switch along with an explanation of each indicator. Ø Power LED: This indicator will light up when the Switch powers up. If the LED is not lit, please check the power adapter and connection. Ø 1000M LINK/ACT LEDs: These LEDs indicate Link/Active status. One LED will light green when a 1000Mbps device is connected to the corresponding port. It flashes when data is being transmitted or received on the connection. Ø 10/100M LINK/ACT LEDs: These LEDs indicate Link/Active status. One LED will light green when a 10Mbps or 100Mbps device is connected to the corresponding port. It flashes when data is being transmitted or received on the connection. Appendix A: Specifications Standards Topology Protocol Data Transfer Rate Network Media (Cable) Number of Ports LED indicators Transfer Method MAC Address Learning Frame Filter Rate Frame Forward Rate General IEEE802.3 , IEEE802.3u , IEEE802.3ab Star CSMA/CD Ethernet: 10Mbps (Half Duplex), 20Mbps (Full Duplex) Fast Ethernet: 100Mbps (Half Duplex), 200Mbps (Full Duplex) Gigabit Ethernet: 2000Mbps (Full Duplex) 10Base-T: UTP category 3, 4, 5 cable (maximum 100m) EIA/TIA-568 100Ù STP (maximum 100m) 100Base-Tx: UTP category 5, 5e cable (maximum 100m) EIA/TIA-568 100Ù STP (maximum 100m) 1000Base-T: UTP category 5, 5e cable (maximum 100m) 5/8 10/100/1000Mbps Auto-Negotiation ports Power, Link/Act Store-and-Forward Automatically learning, automatically Update 10Base-T: 14880pps/Port 100Base-Tx: 148800pps/Port 1000Base-T: 1488000pps/Port 10Base-T: 14880pps/Port 100Base-Tx: 148800pps/Port 1000Base-T: 1488000pps/Port 2 71030478 Rev: 2.0 Dimensions(W D H) Power Supply Output: Operating Temperature Storage Temperature Operating Humidity Storage humidity Environmental and Physical 7.3 5.7 1.7 in. (186mm 146mm AC 9V~ 1.2A 0OC~40OC (32OF~104OF) -40OC~70OC (-40OF~158OF) 10%~90% non-condensing 5%~95% non-condensing 44mm) Appendix B: Troubleshooting 1. The Power LED is not lit Ø Make sure the AC power Adapter is plugged into an outlet properly and it's connector is plugged into the power jack of the switch . Ø Make sure the power source is ON. Ø Make sure you are using the TP-LINK power adapter supplied with your switch. 2. The Link/Act LED is not lit when a device is connected to the corresponding port Ø Make sure that the cable connectors are firmly plugged into the Switch and the device. Ø Make sure the connected device is turned on and its adapter is installed correctly and is working. Ø The cable must be less than 100 meters long(328 feet). Appendix C: Contact Information For help with the installation or operation of the TP-LINK TL-SG1005D/TLSG1008D Switch, please contact us. E-mail: [email protected] Website: http://www.tp-link.com COPYRIGHT & TRADEMARKS Specifications are subject to change without notice. is a registered trademark of TP-LINK Technologies Co., Ltd. Other brands and product names are trademarks or registered trademarks of their respective holders. No part of the specifications may be reproduced in any form or by any means or used to make any derivative such as translation, transformation, or adaptation without permission from TP-LINK Technologies Co., Ltd. Copyright 2005 TP-LINK Technologies Co., Ltd. All rights reserved. 3 FCC STATEMENT This equipment has been tested and found to comply with the limits for a class B digital device, pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures: Ø Reorient or relocate the receiving antenna. Ø Increase the separation between the equipment and receiver. Ø Connect the equipment into an outlet on a circuit different from that to which the receiver is connected. Ø Consult the dealer or an experienced radio/TV technician for help. EC DECLARATION OF CONFORMITY (EUROPE) In compliance with the EMC Directive 89/336/EEC, Low Voltage Directive 73/23/ EEC, this product meets the requirements of the following standards: Ø EN55022 Ø EN55024 Ø EN60950 SAFETY NOTICES Caution: Do not use this product near water, for example, in a wet basement or near a swimming pool. Avoid using this product during an electrical storm. There may be a remote risk of electric shock from lightning. 4

  • 1
  • 2

Appendix B: Troubleshooting
1.
The Power LED is not lit
Ø
2.
The Link/Act LED is not lit when a device is connected
to the corresponding port
Appendix C: Contact Information
E-mail:
Website:
COPYRIGHT & TRADEMARKS
Specifications are subject to change without notice.
is a registered
trademark of TP-LINK Technologies Co., Ltd. Other brands and product names are
trademarks or registered trademarks of their respective holders.
No part of the specifications may be reproduced in any form or by any means or
used to make any derivative such as translation, transformation, or adaptation
without permission from TP-LINK Technologies Co., Ltd. Copyright
2005 TP-LINK
Technologies Co., Ltd. All rights reserved.
Make sure the AC power Adapter is plugged into an outlet properly and it's
connector
is plugged into the power jack of the switch .
Ø
Make sure the power source is ON.
Ø
Make sure you are using the TP-LINK power adapter supplied with your switch.
Ø
Make sure that the cable connectors are firmly plugged into the Switch and the
device.
Ø
Make sure the connected device is turned on and its adapter is installed
correctly and is working.
Ø
The cable must be less than 100 meters long(328 feet).
For help with the installation or operation of the TP-LINK TL-SG1005D/TL-
SG1008D Switch, please contact us.
3.3
LED indicators
Figure 3-1
Ø
Power LED
:
Appendix A: Specifications
The LED indicators include Power LED and Link/Act LEDs (See
). The
LED indicators are used for monitoring and troubleshooting of the Switch. The
following section shows the LED indicators for the Switch along with an explanation
of each indicator.
This indicator will light up when the Switch powers up. If the LED
is not lit, please check the power adapter and connection.
Ø
1000M LINK/ACT LEDs
: These LEDs indicate Link/Active status. One LED will
light green when a 1000Mbps device is connected to the corresponding port. It
flashes when data is being transmitted or received on the connection.
Ø
10/100M LINK/ACT LEDs
: These LEDs indicate Link/Active status. One LED
will light green when a 10Mbps or 100Mbps device is connected to the
corresponding port. It flashes when data is being transmitted or received on the
connection.
FCC STATEMENT
This equipment has been tested and found to comply with the limits for a class B
digital device, pursuant to part 15 of the FCC Rules. These limits are designed to
provide reasonable protection against harmful interference in a residential
installation.
This equipment generates, uses and can radiate radio frequency energy and, if not
installed and used in accordance with the instructions, may cause harmful
interference to radio communications. However, there is no guarantee that
interference will not occur in a particular installation. If this equipment does cause
harmful interference to radio or television reception, which can be determined by
turning the equipment off and on, the user is encouraged to try to correct the
interference by one or more of the following measures:
Ø
Reorient or relocate the receiving antenna.
Ø
Increase the separation between the equipment and receiver.
Ø
Connect the equipment into an outlet on a circuit different from that to which the
receiver is connected.
Ø
Consult the dealer or an experienced radio/TV technician for help.
EC DECLARATION OF CONFORMITY (EUROPE)
In compliance with the EMC Directive 89/336/EEC, Low Voltage Directive 73/23/
EEC, this product meets the requirements of the following standards:
Ø
EN55022
Ø
EN55024
Ø
EN60950
SAFETY NOTICES
Caution:
Do not use this product near water, for example, in a wet basement or near a
swimming pool.
Avoid using this product during an electrical storm. There may be a remote risk of
electric shock from lightning.
2
3
4
71030478
Rev: 2.0
General
Standards
IEEE802.3 , IEEE802.3u , IEEE802.3ab
Topology
Star
Protocol
CSMA/CD
Data Transfer
Ethernet: 10Mbps (Half Duplex), 20Mbps (Full Duplex)
Rate
Fast Ethernet: 100Mbps (Half Duplex), 200Mbps (Full Duplex)
Gigabit Ethernet: 2000Mbps (Full Duplex)
Network Media
10Base-T: UTP category 3, 4, 5 cable (maximum 100m)
(Cable)
EIA/TIA-568 100
Ù
STP (maximum 100m)
100Base-Tx: UTP category 5, 5e cable (maximum 100m)
EIA/TIA-568 100
Ù
STP (maximum 100m)
1000Base-T: UTP category 5, 5e cable (maximum 100m)
Number of Ports
5/8 10/100/1000Mbps Auto-Negotiation ports
LED indicators
Power, Link/Act
Transfer Method
Store-and-Forward
MAC Address Learning
Automatically learning, automatically Update
Frame Filter Rate
10Base-T: 14880pps/Port
100Base-Tx: 148800pps/Port
1000Base-T: 1488000pps/Port
Frame Forward Rate
10Base-T: 14880pps/Port
100Base-Tx: 148800pps/Port
1000Base-T: 1488000pps/Port
Environmental and Physical
Dimensions(
W
D
H
)
7.3
5.7
1.7 in. (186mm
146mm
44mm)
Power Supply Output:
AC 9V~
1.2A
O
O
O
O
Operating Temperature
0 C~40
C (32
F~104 F)
O
O
O
O
Storage Temperature
-40 C~70
C (-40
F~158 F)
Operating Humidity
10%~90% non-condensing
Storage humidity
5%~95% non-condensing
Figure 3-2 TL-SG1008D Switch Rear Panel sketch
1
2
3
4
5
6
7
8
POWER