en-us Prepare installation space ¡ If the thickness of the countertop into which the cooktop is installed does not comply with the specifications, reinforce the worktop using a fire- and water-resistant material until it reaches the minimum thickness. Otherwise, sufficient stability cannot be assured. ¡ The countertop into which the cooktop is installed should withstand loads of approx. 133 lbs (60 kg). ¡ Confirm the cooktop is level only after it has been installed. 3.1 Cutout dimensions for 30" cooktops Refer to these measurements for the models stated here. ¡ CIT304YB ¡ CIT304YM 3.3 Cabinet ventilation requirements To assure that the appliance works correctly, the cooktop MUST be sufficiently ventilated. The ventilation in the lower section of the appliance requires a sufficient supply of fresh air. Ensure that the cabinet is designed in a way that supports sufficient ventilation. The following requirements must be fulfilled: Notes ¡ A minimum clearance between the rear of the cabinet and the kitchen wall, and between the surface of the countertop and the upper area of the drawer. 3.2 Cutout dimensions for 36" cooktops Refer to these measurements for the models stated here. ¡ CIT365YB ¡ CIT367YG ¡ CIT367YGS ¡ CIT367YM ¡ CIT367YMS 6