Prepare Installation Space PrepaInstlaionSpace Create the cut-out in the countertop according to the installation diagram. The angle of the cut surface to the countertop must be 90°. The lateral cut-out edges must be flat in order to ensure that the retaining springs are positioned properly on the appliance. With multi-layered countertops, secure strips laterally in the cut-out if necessary. After creating cut-out, remove shavings. Seal cut surfaces in a heat- and water-resistant manner. Observe minimum distance between device underside and cabinet surfaces of 3/8" (10 mm). Cutout dimensions for 30" cooktops Model: CIT30XWBB PLQ  PLQ  PLQ  Cutout dimensions for 36" cooktops Model: CIT36XWB, CIT36XWBB PLQ  PLQ  PLQ  ¡  [ PLQ  ƒ PLQ  ¡  [ PLQ  ƒ PLQ    PP   PP Ventilation To assure that the appliance works correctly, the cooktop MUST be sufficiently ventilated. Since the ventilation in the lower section of the appliance requires a sufficient supply of fresh air, the cabinet must be designed accordingly. The following is required for this: ▯ A minimum clearance between the rear of the cabinet and the kitchen wall, and between the surface of the worktop and the upper area of the drawer. PLQ  PLQ   PP 6

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32

6
Prepare Installation Space
P
repa
re
Ins
ta
lla
tion
Space
Create the cut-out in the countertop according to the
installation diagram. The angle of the cut surface to the
countertop must be 90°.
The lateral cut-out edges must be flat in order to ensure
that the retaining springs are positioned properly on the
appliance. With multi-layered countertops, secure strips
laterally in the cut-out if necessary.
After creating cut-out, remove shavings. Seal cut
surfaces in a heat- and water-resistant manner.
Observe minimum distance between device underside
and cabinet surfaces of
3
/
8
" (10 mm).
Cutout dimensions for 30" cooktops
Model: CIT30XWBB
Cutout dimensions for 36" cooktops
Model: CIT36XWB, CIT36XWBB
Ventilation
To assure that the appliance works correctly, the cooktop
MUST
be sufficiently ventilated.
Since the ventilation in the lower section of the appliance
requires a sufficient supply of fresh air, the cabinet must
be designed accordingly. The following is required for
this:
A minimum clearance between the rear of the cabinet
and the kitchen wall, and between the surface of the
worktop and the upper area of the drawer.