Thermador PRD606RCG Design Guide - Page 12

Installation Options, Inch Cutout And Range Dimensions

Page 12 highlights

PRO GRAND RANGES INSTALLATION OPTIONS Thermador Pro Grand® Ranges feature a bold, professional design and a commercial-depth of 27-inches. These ranges can be installed in a wall or island installation. BACKGUARDS When using the Flush Island Trim, Thermador recommends a minimum 12" (305 mm) rear clearance to a combustible surface (see Figure 1, Cabinet Clearances). Clearances from noncombustible materials are not part of the ANSI Z21.1 scope and are not certified by CSA. Clearances of less than 12" (305 mm) must be approved by the local codes and / or by the local authority having jurisdiction. NATURAL GAS OR LP Thermador Dual-Fuel Pro Grand Ranges are shipped by the factory to operate on natural gas. They must be converted for use with propane. Verify that the type of gas being used at the installation site matches the type of gas used by the appliance. If the location / job site requires conversion from natural gas to propane (LP), utilize the included LP kit. Field conversion must be done by qualified service personnel only. Please refer to the LP Conversion Instructions for further information. IMPORTANT We strongly recommend that a Thermador Professional® Wall or Island Hood or Custom Insert be installed with all Thermador Pro Grand Ranges. Downdraft ventilation should not be used. Do not install a microwave-hood combination above the cooktop, as these types of units do not provide the proper ventilation and are not suitable for use with Thermador Pro Grand Ranges. Refer to the Ventilation section or www.Thermador.com for a complete selection of Professional ventilation options, blowers, and accessories. Due to the 27-inch commercial-depth of Pro Grand Ranges, the PH Professional Series Wall Hoods or Professional Series Custom Inserts would provide the appropriate depth from the wall to correspond to these ranges. HIGH ALTITUDE A high altitude kit is available through Customer Services as service part number 746376. PRO GRAND® RANGES 36-INCH DUAL-FUEL PRD364JDGU 36-INCH CUTOUT AND RANGE DIMENSIONS NOTE: A 36-inch minimum clearance is required between the top of the cooking surface and the bottom of an unprotected cabinet. A 30-inch clearance can be used when the bottom of the wood or metal cabinet is protected by not less than 1/4 inch of a flame retardant material covered with not less than No. 28 MSG sheet steel, 0.015 inch (0.4 mm) thick stainless steel, 0.024 inch (0.6 mm) aluminum, or 0.020 inch (0.5 mm) thick copper. aassddeenendeidn itnheth"Nea"tNioantailoFnuaell GFauseCl oGdaes" (CAoNdSIeZ"2(A23N.1S,I Z223.1, CCuurrrerennt EtdEidtioitnio).nC)le. aCrlaenacreasnfrcoems fnroonm-conmobnu-cstoibmlebmuastteibrialelsmaterials aCarSreeAn.noCotleptaaprraatnroctfeotshfoetfhAleNessSAIthNZa2Sn1I.11Z22s"c1(o3.p10e5sacmnomdp)aermeaunnsodttbaceereartpinpoerodtvcbeeydrti ed by bCyStAh.eClolecaalrcaondceessaondf /loerssbyththaenlo1c2a"l (a3u0th5omritmy h)amvinugst be approved jbuyristdhicetiloonc.al codes and/or by the local authority having jurisdiction. 1.800.735.4328 | THERMADOR.COM 27

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24

PRO GRAND RANGES
1.800.735.4328
|
THERMADOR.COM
27
PRO GRAND
®
RANGES
36-INCH DUAL-FUEL
PRD364JDGU
INSTALLATION OPTIONS
Thermador Pro Grand
®
Ranges feature a bold,
professional design and a commercial-depth of
27-inches. These ranges can be installed in a wall
or island installation.
BACKGUARDS
When using the Flush Island Trim, Thermador
recommends a minimum 12" (305 mm) rear
clearance to a combustible surface (see Figure
1, Cabinet Clearances). Clearances from non-
combustible materials are not part of the ANSI
Z21.1 scope and are not certified by CSA.
Clearances of less than 12" (305 mm) must be
approved by the local codes and / or by the local
authority having jurisdiction.
NATURAL GAS OR LP
Thermador Dual-Fuel Pro Grand Ranges are
shipped by the factory to operate on natural gas.
They must be converted for use with propane. Verify
that the type of gas being used at the installation
site matches the type of gas used by the appliance.
If the location / job site requires conversion from
natural gas to propane (LP), utilize the included
LP kit. Field conversion must be done by qualified
service personnel only. Please refer to the LP
Conversion Instructions for further information.
IMPORTANT
We strongly recommend that a Thermador
Professional
®
Wall or Island Hood or Custom Insert
be installed with all Thermador Pro Grand Ranges.
Downdraft ventilation should not be used. Do not
install a microwave-hood combination above the
cooktop, as these types of units do not provide
the proper ventilation and are not suitable for use
with Thermador Pro Grand Ranges. Refer to the
Ventilation section or www.Thermador.com for
a complete selection of Professional ventilation
options, blowers, and accessories.
Due to the 27-inch commercial-depth of Pro Grand
Ranges, the PH Professional Series Wall Hoods or
Professional Series Custom Inserts would provide
the appropriate depth from the wall to correspond
to these ranges.
HIGH ALTITUDE
A high altitude kit is available through Customer
Services as service part number 746376.
36-INCH CUTOUT AND RANGE DIMENSIONS
NOTE:
A 36-inch
minimum clearance
is required between
the top of the
cooking surface
and the bottom
of an unprotected
cabinet. A 30-inch
clearance can be
used when the
bottom of the wood
or metal cabinet is
protected by not
less than
1
/
4
inch of
a flame retardant
material covered
with not less than
No. 28 MSG sheet
steel, 0.015 inch (0.4
mm) thick stainless
steel, 0.024 inch (0.6
mm) aluminum, or
0.020 inch (0.5 mm)
thick copper.
as defined in the “National Fuel Gas Code” (ANSI Z223.1,
Current Edition). Clearances from non-combustible materials
are not part of the ANSI Z21.1 scope and are not certified by
CSA. Clearances of less than 12” (305 mm) must be approved
by the local codes and/or by the local authority having
jurisdiction.